Specifications – WIKA 851 User Manual

Page 8

Advertising
background image

WIKA operating instructions magnetic snap-action contact model 821

GB

8

2003325.03 03/2011 GB/D/F/E

3. Specifications

3. Specifications

Table 1a: Limits for the magnetic snap-action contact model 821

Limits for the contact rating

with resistive load

Magnetic snap-action contact

model 821

dry gauges

filled gauges

Rated voltage U

eff

max.

250 V

250 V

Rated current

1)

Make current

1.0 A

1.0 A

Breaking current

1.0 A

1.0 A

Continuous current

0.6 A

0.6 A

Contact rating max.

30 W / 50 VA

20 W / 20 VA

1) The values for rated currents shown in the above table apply to instruments with switch ver-

sion S. For instruments with switch version L these values should be halved.

(see chapter "5. Allocation of switch version to basic instruments and measuring ranges")

WARNING!

None of the limits for voltage, current and power are to be

exceeded!

We recommend the following load values to ensure safe,

continuous operation:

Table 1b: Limits for the sliding contact model 811

Limits for the contact rating

with resistive load

Sliding contact model 811

dry gauges

Rated voltage U

eff

max.

250 V

Rated current

1)

Make current

0.7 A

Breaking current

0.7 A

Continuous current

0.6 A

Contact rating max.

10 W / 18 VA