WIKA operating instructions magnetic snap-action contact model 821

9

GB

2003325.03 03/2011 GB/D/F/E

Voltage

(DIN IEC 38)

Magnetic snap-action contact model 821

dry gauges

filled gauges

DC / AC

V

resistive

load

DC

mA

AC

mA

inductive

load

cos ϕ >0.7

mA

resistive

load

DC

mA

AC

mA

inductive

load

cos ϕ >0.7

mA

230

100

120

65

65

90

40

110

200

240

130

130

180

85

48

300

450

200

190

330

130

24

400

600

250

250

450

150

Table 2a: Recommended contact rating for the magnetic snap-action

contact model 821

3. Specifications

Voltage

(DIN IEC 38)

Sliding contact model 811

dry gauges

DC / AC

V

resistive load

DC

mA

AC

mA

inductive load

cos ϕ >0.7

mA

230

40

45

25

110

80

90

45

48

120

170

70

24

200

350

100

Table 2a: Recommended contact rating for the sliding contact model 811

The switching current must not be less than 20 mA with low

voltages for switching reliability reasons. For higher loads,

and instruments with liquid-filled cases, we recommend

using WIKA contact protection relays, models 905.1x.

The ingress protection to EN 60529 against external influences depends

on the basic instrument and is found in the respective data sheet.
The limit switches can be used in the range from -20 to +70 °C. Where

the permissible temperatures for the basic instrument (see data sheet)

deviate from this range, the lower values are valid.
For further specifications see the corresponding WIKA data sheet and

the order documentation.