Parameter descriptions, Figure 14. parameter configuration sets, 1 modal configuration sets – Cirrus Logic CS2300-OTP User Manual
Page 19: 1 r-mod selection (rmodsel[1:0]), Cs2300-otp, Di git al/ pll core

CS2300-OTP
DS844F2
19
6. PARAMETER DESCRIPTIONS
As mentioned in
, there are two different kinds of parameter configuration sets, Modal and
Global. These configuration sets, shown in
, can be programmed in the field using the CDK2000 or pre-
programmed at the factory. Please see
“Programming Information” on page 23
for more details.
Figure 14. Parameter Configuration Sets
6.1
Modal Configuration Sets
There are four instances of each of these configuration parameters. Selection between the four stored sets
is made using the M[1:0] pins.
6.1.1
R-Mod Selection (RModSel[1:0])
Selects the R-Mod value, which is used as a factor in determining the PLL’s Fractional N.
Note:
This parameter does not take affect unless M2 pin is high and the M2Config[2:0] global param-
eter is set to ‘011’.
RModSel[1:0]
R-Mod Selection
00
Right-shift R-value by 1 (÷ 2).
01
Right-shift R-value by 2 (÷ 4).
10
Right-shift R-value by 3 (÷ 8).
11
Right-shift R-value by 4 (÷ 16).
Application:
“Ratio Modifier (R-Mod)” on page 13
M[1:0] pins
Modal Configuration Set #0
RModSel[1:0]
AuxOutSrc[1:0]
Modal Configuration Set #1
Ratio 1
RModSel[1:0]
AuxOutSrc[1:0]
Modal Configuration Set #2
Ratio 2
RModSel[1:0]
AuxOutSrc[1:0]
Modal Configuration Set #3
Ratio 3
RModSel[1:0]
AuxOutSrc[1:0]
00
01
10
11
Global Configuration Set
ClkOutUnl
AuxLockCfg
LFRatioCfg
M2Config[2:0]
Ratio 0
Di
git
al/
PLL Core
ClkIn_BW[2:0]