AC ELECTRICAL CHARACTERISTICS

Test Conditions (unless otherwise specified): VD = 3.1 V to 3.5 V; T

A

= -10°C to +70°C (Commercial Grade);

T

A

= -40°C to +85°C (Automotive Grade); C

L

= 15 pF.

Notes:

5.

f

CLK_OUT

= 24.576 MHz; Sample size = 10,000 points; AuxOutSrc[1:0] = 11.

6. In accordance with AES-12id-2006 section 3.4.2. Measurements are Time Interval Error taken with 3rd

order 100 Hz to 40 kHz bandpass filter.

7. In accordance with AES-12id-2006 section 3.4.1. Measurements are Time Interval Error taken with 3rd

order 100 Hz Highpass filter.

8. 1 UI (unit interval) corresponds to t

CLK_IN

or 1/f

CLK_IN

.

Parameters

Symbol

Conditions

Min

Typ

Max

Units

Clock Input Frequency

f

CLK_IN

50 Hz

-

30

MHz

Clock Input Pulse Width

pw

CLK_IN

f

CLK_IN

< 175 kHz

f

CLK_IN

> 175 kHz

140

10

-
-

-
-

ns
ns

PLL Clock Output Frequency

f

CLK_OUT

6

-

75

MHz

PLL Clock Output Duty Cycle

t

OD

Measured at VD/2

45

50

55

%

Clock Output Rise Time

t

OR

20% to 80% of VD

-

1.7

3.0

ns

Clock Output Fall Time

t

OF

80% to 20% of VD

-

1.7

3.0

ns

Period Jitter

t

JIT

(

Note 5

)

-

35

-

ps rms

Base Band Jitter (100 Hz to 40 kHz)

(Notes

5

,

6

)

-

50

-

ps rms

Wide Band JItter (100 Hz Corner)

(Notes

5

,

7

)

-

150

-

ps rms

PLL Lock Time - CLK_IN (

Note 8

)

t

LC

f

CLK_IN

< 200 kHz

f

CLK_IN

> 200 kHz

-
-

100

1

200

3

UI

ms

Advertising