6 customize, 7 external macros, 6 customize 3.5.7 external macros – Cirrus Logic CRD5376 User Manual

Page 48: Crd5376

Advertising
background image

CRD5376

48

DS612RD2

3.5.6

Customize

The Customize sub-panel sends commands to upload custom FIR and IIR filter coefficients, upload cus-
tom test bit stream data, start the digital filter, stop the digital filter, and write/read custom EEPROM con-
figuration files to the on-board boot EEPROM. Example data files are included in a sub-directory of the
software installation.

3.5.7

External Macros

Macros are generated within the Macros sub-panel on the Control panel. Once a macro has been built
it can either be saved with a unique macro name to be run within the Macros sub-panel, or saved as an
external macro and be associated with one of the External Macro buttons.

A macro is saved as an External Macro by saving it in the . /macros/ subdirectory using the name
‘m1.mac’, ‘m2.mac’, etc. Depending on the selected name the macro will be associated with the corre-
sponding External Macro button M1, M2, etc.

• M1 = . /macros/m1.mac
• M2 = . /macros/m2.mac
• etc.

External Macro buttons can be re-named on the panel by right clicking on them. The button name will-
change, but the macro associated with that button is always saved as ‘m1.mac’, ‘m2.mac’, etc., in the
. /macros/ subdirectory. The External Macro button names are stored in the file ‘Mnames.txt’, also in the
. /macros/ subdirectory.

External Macros allow up to eight macros to be accessed quickly without having to load them into the Mac-
ros
sub-panel on the Control panel. These External Macros operate independently of the Macros sub-
panel and are not affected by operations within it, except when a macro is saved to the . /macros/ subdi-
rectory to replace a currently existing External Macro.

Control

Description

Load FIR Coef

Write a set of FIR coefficients into the digital filter from a file.

Load IIR Coef

Write a set of IIR coefficients into the digital filter from a file.

Load TBS Data Write a set of test bit stream data into the digital filter from a file.
Start Filter

Enables the digital filter by sending the Start Filter command.

Stop Filter

Disables the digital filter by sending the Stop Filter command.

Write EEPROM Writes an EEPROM boot configuration file to EEPROM memory (unused on CRD5376A).
Verify EEPROM Verifies EEPROM memory against an EEPROM boot configuration file (unused on CRD5376A)

Control

Description

M1 - M8

Runs the External Macro associated with that button.

Advertising