DS620F1

CS4384

POWER AND THERMAL CHARACTERISTICS

Notes:

4.

Current consumption increases with increasing FS within a given speed mode and is signal dependant. Max
values are based on highest FS and highest MCLK.

5.

I

LC

measured with no external loading on the SDA pin.

6.

Power Down Mode is defined as RST pin = Low with all clock and data lines held static.

7.

Valid with the recommended capacitor values on FILT+ and VQ as shown in

Figures 7

and

8

.

Parameters

Symbol

Min

Typ

Max

Units

Power Supplies

Power Supply Current

normal operation, VA= 5 V

(Note 4)

VD= 2.5 V

(Note 5)

Interface current, VLC=5 V

VLS=5 V

(Note 6)

power-down state (all supplies)

I

A

I

D

I

LC

I

LS

I

pd

-
-
-
-
-

83
20

2

84

200

92
25

-
-
-

mA
mA

µA

µA

µA

Power Dissipation

(Note 4)

VA = 5 V, VD = 2.5 V

normal operation

(Note 6)

power-down

-
-

465

1

520

-

mW
mW

Package Thermal Resistance

multi-layer

dual-layer

θ

JA

θ

JA

θ

JC

-
-
-

48
65
15

-
-
-

°C/Watt
°C/Watt
°C/Watt

Power Supply Rejection Ratio

(Note 7)

(1 kHz)

(60

Hz)

PSRR

-
-

60
40

-
-

dB
dB