Switching characteristics, Cs5461a – Cirrus Logic CS5461A User Manual

Page 10

Advertising
background image

CS5461A

10

DS661F3

SWITCHING CHARACTERISTICS

Min / Max characteristics and specifications are guaranteed over all

Recommended Operating Conditions

.

Typical characteristics and specifications are measured at nominal supply voltages and TA = 25 °C.

VA+ = 5 V ±5% VD+ = 3.3 V ±5% or 5 V ±5%; AGND = DGND = 0 V. All voltages with respect to 0 V.

Logic Levels: Logic 0 = 0 V, Logic 1 = VD+.

Notes:

16.

Specified using 10% and 90% points on wave-form of interest. Output loaded with 50 pF.

17.

Oscillator start-up time varies with crystal parameters. This specification does not apply when using an external

clock source.

Parameter

Symbol Min Typ

Max

Unit

Rise Times

Any Digital Input Except SCLK

(Note 16)

SCLK

Any Digital Output

t

rise

-
-
-

-
-

50

1.0

100

-

µs
µs
ns

Fall Times

Any Digital Input Except SCLK

(Note 16)

SCLK

Any Digital Output

t

fall

-
-
-

-
-

50

1.0

100

-

µs
µs
ns

Start-up

Oscillator Start-Up Time

XTAL = 4.096 MHz (Note 17)

t

ost

-

60

-

ms

Serial Port Timing

Serial Clock Frequency

SCLK

-

-

2

MHz

Serial Clock

Pulse Width High

Pulse Width Low

t

1

t

2

200
200

-
-

-
-

ns
ns

SDI Timing

CS Falling to SCLK Rising

t

3

50

-

-

ns

Data Set-up Time Prior to SCLK Rising

t

4

50

-

-

ns

Data Hold Time After SCLK Rising

t

5

100

-

-

ns

SDO Timing

CS Falling to SDO Driving

t

6

-

20

50

ns

SCLK Falling to New Data Bit (hold time)

t

7

-

20

50

ns

CS Rising to SDO Hi-Z

t

8

-

20

50

ns

Auto-Boot Timing

Serial Clock

Pulse Width Low

Pulse Width High

t

9

t

10

8
8

MCLK
MCLK

MODE setup time to RESET Rising

t

11

50

ns

RESET rising to CS falling

t

12

48

MCLK

CS falling to SCLK rising

t

13

100

8

MCLK

SCLK falling to CS rising

t

14

16

MCLK

CS rising to driving MODE low (to end auto-boot sequence).

t

15

50

ns

SDO guaranteed setup time to SCLK rising

t

16

100

ns

Advertising