Cs5461a, 19 no load threshold interval register ( loadintv), 20 no load threshold ( loadmin ) – Cirrus Logic CS5461A User Manual
Page 32
Advertising

CS5461A
32
DS661F3
6.19 No Load Threshold Interval Register ( LoadIntv)
Address: 25
Default = 0x000000 = No load threshold feature disabled
LoadMin determines the duration or interval of the no load detection window in units of 1/OWR. The range is
from 1 to 16777215.
6.20 No Load Threshold ( LoadMin )
Address: 27
Default = 0x000000 = No load threshold feature disabled
LoadMin sets the no load threshold value. LoadMin is a two’s complement value in the range of
-1.0
LoadMin 1.0 with the binary point to the right of the MSB. Negative values are not allowed.
MSB
LSB
2
23
2
22
2
21
2
20
2
19
2
18
2
17
2
16
.....
2
6
2
5
2
4
2
3
2
2
2
1
2
0
MSB
LSB
-(2
0
)
2
-1
2
-2
2
-3
2
-4
2
-5
2
-6
2
-7
.....
2
-17
2
-18
2
-19
2
-20
2
-21
2
-22
2
-23
Advertising