5 pulse output e3, 6 anti-creep for the pulse outputs, 7 design examples – Cirrus Logic CS5461A User Manual

Page 18: Figure 6. stepper motor format on e1, Cs5461a, 5 pulse output

Advertising
background image

CS5461A

18

DS661F3

energy level, the energy output pins (E1 and E2) alter-
nate changing states (see Figure 6). The duration
(t

edge

) between the alternating states is defined by the

transfer function:

The direction the motor will rotate is determined by the
order of the state changes. When energy is positive, E1
will lead E2. When energy is negative, E2 will lead E1.
The Pulse Width Register (PW) does not affect the step-
per motor format.

5.4.5

Pulse Output

E3

The pulse output E3 is designed to assist with meter cal-
ibration. The pulse-output frequency of E3 is directly
proportional to the active power calculated from the in-
put signals. E3 pulse frequency is derived using a sim-
ular transfer function as E1, but is set by the value in the
PulseRateE

3

Register.

The E3 pin outputs negative and positive energy, but
has no energy direction indicator.

The pulse width of E3 is configurable. The PulseWidth
register defines the pulse width of E3 in units of 1/OWR
or:

The default value is 0.

5.4.6 Anti-creep for the Pulse Outputs

Anti-creep allows the measurement element to maintain
an energy level, such that when the magnitude of the
accumulated active power is below this level, no energy
pulses are output. Anti-creep is enabled by setting bit
FAC in the Control Register for E3 and bit EAC in the
Control Register for E1 and E2.

For low-frequency pulse output formats (i.e. mechanical
counter and stepper motor formats), the active power is
accumulated over time. When a designated energy lev-
el is reached (determined by the transfer function) a
pulse is generated on E1 and/or E2. If active power with

alternating polarity occurs during the accumulation peri-
od (e.g. random noise at zero power levels), the accura-
cy of the registered energy will be maintained.

For high-frequency pulse output formats (i.e. normal
and alternate pulse formats), the active power is accu-
mulated over time until a

8x buffer is defined. Then,

when the designated energy level is reached, a pulse is
generated on E1 and/or E2. For pulse outputs with high
frequencies and power levels close to zero, the extend-
ed buffer prevents random noise from being registered
as active energy.

5.4.7 Design Examples

EXAMPLE #1:

The maximum rated levels for a power line meter are
250 V rms and 20 A rms. The required number of puls-
es per second on E1 is 100 pulses per second (100 Hz),
when the levels on the power line are 220 V rms and
15 A rms.

With a 10x gain on the voltage and current channel the
maximum input signal is 250 mV

P

(see

Section 5.1 An-

alog Inputs

on page 15). To prevent over-driving the

channel inputs, the maximum rated rms input levels will
register 0.6 in V

RMS

and I

RMS

by design. Therefore the

voltage level at the channel inputs will be 150 mV rms
when the maximum rated levels on the power lines are
250 V rms and 20 A rms.

Solving for PulseRateE

1,2

using the transfer function:

Therefore with PF = 1 and

the PulseRateE

1,2

Register is set to:

E 1

E 2

P o s it iv e E n e r g y

N e g a t iv e E n e r g y

. . .

. . .

. . .

. . .

t

e d g e

Figure 6. Stepper Motor Format on E1 and E2

t

edge

sec

1

FREQ

E

----------------------

=

t

pw

PulseWidth

MCLK

K

1024

---------------------------------------------

=

PulseRateE

1 2

,

FREQ

E

VREFIN

2

VIN

VGAIN

IIN

PF

-------------------------------------------------------------------

=

VIN

220V

150mV

 250V

132mV

=

=

IIN

15A

150mV

 20A

112.5mV

=

=

PulseRateE

100

2.5

2

0.132

10

0.1125

10

-----------------------------------------------------------------

420.8754Hz

=

=