Ds261pp5 – Cirrus Logic CS61584A User Manual

Page 40

Advertising
background image

CS61584A

40

DS261PP5

DS261PP5

RGND1, RGND2 - Receiver Ground (PLCC pins 30, 39; TQFP pins 20, 29)

Power supply ground pins for the receiver circuitry.

RV+1, RV+2 - Receiver Power Supply (PLCC pins 29, 40; TQFP pins 19, 30)

Power supply pins for the analog receiver circuitry.

TGND1, TGND2 - Transmit Ground (PLCC pins 22, 47; TQFP pins 13, 36)

Power supply ground pins for the transmitter circuitry.

TV+1, TV+2 - Transmit Power Supply (PLCC pins 21, 48; TQFP pins 12, 37)

Power supply pins for the analog transmitter circuitry.

53

55

57

59

44

46

48

50

16

14

12

10

25

23

21

19

27

29

31

33

36

38

40

42

8

6

4

2

67

65

63

61

17

15

13

11

26

24

22

20

28

30

32

34

37

39

41

43

54

56

58

60

45

47

49

51

9

7

5

3

68

66

64

62

CS61584A

68-pin PLCC

Top View

18

52

1

35

DGND1

AD3

AD2

AD1

AD0

RD(DS)

INT

CS

DGND1

not used

SPOL

SDI

SDO

SCLK

INT

CS

DGND1

CON01

TAOS2

TAOS1

LLOOP

RLOOP2

RLOOP1

ATTEN1

Hardware Mode

Host Mode
Serial Port

Host Mode

Parallel Port

DV+

DGND3

CON02

CON11

CON12

CON21

CON22

CON31

DV+

DGND3

not used

not used

not used

not used

not used

not used

DV+

DGND3

AD4

AD5

AD6

AD7

ALE(AS)

WR(R/W)

Hardware Mode

Host Mode
Serial Port

Host Mode

Parallel Port

not used

not used

not used

TGND1

TRING1

SAD4

P/S

DGND2

J-TDI

TTIP1

TV+1

TPOS1(TDATA1)

TNEG1(AIS1)

SAD6

J-TDO

RCLK1

RPOS1(RDATA1)

RNEG1(BPV1)

TCLK1

TGND1

TRING1

ZTX1

P/S

DGND2

J-TDI

TTIP1

TV+1

TPOS1(TDATA1)

TNEG1(AIS1)

LOS1

J-TDO

RCLK1

RPOS1(RDATA1)

RNEG1(BPV1)

TCLK1

TGND1

TRING1

PD1

ATTEN0

DGND2

J-TDI

TTIP1

TV+1

TPOS1

TNEG1

LOS1

J-TDO

RCLK1

RPOS1

RNEG1

TCLK1

not used

not used

not used

RTIP1

RRING1

RV+1

RGND1

MODE

BGREF

AGND

AV+

RTIP1

RRING1

RV+1

RGND1

MODE

BGREF

AGND

AV+

RTIP1

RRING1

RV+1

RGND1

MODE

BGREF

AGND

AV+

not used

not used

not used

RCLK2

RPOS2

RNEG2

TCLK2

TPOS2

TNEG2

LOS2

CON32

J-TCK

J-TMS

TTIP2

TV+2

TGND2

TRING2

PD2

CLKE

RCLK2

RPOS2(RDATA2)

RNEG2(BPV2)

TCLK2

TPOS2(TDATA2)

TNEG2(AIS2)

LOS2

not used

J-TCK

J-TMS

TTIP2

TV+2

TGND2

TRING2

ZTX2

IPOL

RCLK2

RPOS2(RDATA2)

RNEG2(BPV2)

TCLK2

TPOS2(TDATA2)

TNEG2(AIS2)

SAD7

BTS

J-TCK

J-TMS

TTIP2

TV+2

TGND2

TRING2

SAD5

IPOL/DTACK

not used

not used

not used

RTIP2

RRING2

RV+2

RGND2

1XCLK

XTALOUT

REFCLK

RESET

RTIP2

RRING2

RV+2

RGND2

1XCLK

XTALOUT

REFCLK

RESET

RTIP2

RRING2

RV+2

RGND2

1XCLK

XTALOUT

REFCLK

RESET

Pins labeled as “not used” should be tied to ground.

CS61584A

40

DS261F1

Advertising