IP control unit (IS-IPC)

IP

This unit is needed to connect a local system to a standard (IP) system.

Part names

NOTE:
The illustration of the unit may differ from the actual one.

Specifi cations

IP control unit (IS-IPC)

Power source

48V DC (supplied from the power supply unit)

Current consumption

Max. 105mA

Ambient temperature

0 - 40°C (+32°F - +104°F)

Talk channels Video
channels, other channels

2 talk & 2 constrained video channels,
1 chime, and 1 telephone (North America
only)

Central control unit

Max. 1

Room sub control unit
LAN

Ethernet (10 BASE-T, 100 BASE-TX)

Mounting

Rack-mount (19-inch, 2U rack) or wall-mount

Material

Steel plate

Color

Black

POWER switch
Turns the power ON ( ) or OFF ( ).

POWER terminals

LAN port

CO port (Telephone)

Link/ACT LED (green)
Operates when this unit is connected to LAN.

POWER LED (green)
Lights up when the power is ON.

Central control unit (IS-CCU) /
Room sub control unit (IS-RCU) ports

STATUS LED (green)
Blinks when this unit is initialized or an error*

1

occurs.
The LED will light up when this unit returns to
the normal state.
*

1

: Communication error in a unit connected

to this unit, or between this unit and a unit
connected to it, etc.