■ Connections (IS-SS)

D

NC COM NO

PT

300m (980')

D1

D4

CAT5e/6

300m (980')

D1

D8

CAT5e/6

300m (980')

C1

C30

CAT5e/6

φ0.65-1.2mm

(22-16 AWG)

10m (33')

φ0.65-1.2mm

(22-16 AWG)

10m (33')

φ0.65-1.2mm

(22-16 AWG)

10m (33')

*1: Output specifi cations

Output method

N/O or N/C dry closure contact

Voltage between
terminals

24V AC, 0.5A (resistive load)
24V DC, 0.5A (resistive load)
Minimum overload (AC/DC):
100mV, 0.1mA

NOTES:

Do not use the unoccupied terminals and ports for other purposes.

•

In order to prevent miswiring, label both ends of each cable with the unit and terminal names to which they are to be connected.

•

For connecting other manufacture’s products, refer to the instruction manuals for those products.

•

The illustration of the unit’s rear panel differs from the actual one. This is for simplifying the connection diagram.

•

Terminal cover

CAT5e/6 cable

Central control unit
(IS-CCU)

Room sub control unit
(IS-RCU)

Add-on control unit
(IS-SCU)

AC transformer

or

or

The terminals are inside the terminal

*

cover. After connecting, route the
wires through the wiring paths, then
close the cover.
Be sure to route the CAT5e/6 cable

*

and option wires through inlet.
When closing the terminal cover,

*

close it until it clicks.

Electric door strike

*1

(non-shielded)

(non-shielded)

(non-shielded)

(Select one port.)

(Select one port.)

(Select one port.)

Connect to the electric

*

door strike according to its
specifi cations.

Inlet

Option
wires

Advertising