Valve island dimensions, Single station sub-base, Connector type: m12 – Norgren VS18 Series Valve Islands User Manual

Page 6

Advertising
background image

3-039

VS1872010-AF00

Single station sub-base for 24 V d.c.

G1/8

G1/8

G1/8

M12

MODELS

Description

Ports 1, 3 & 5

Ports 12/14 & 82/84

Ports 2 & 4

Single station sub-base

Connector type

A

A

49,5

16

24,5

33

85,5

24,5

23

15

14

85,5

71,5

57

42,5

17,5

M 12

14

64,5

79,5

17

36

60

4,5

42

34,5

4

99,5

126,5

5

3

1

2

82/84

4

12/14

Connector type: M12

Pin no.

Function

1

Not used

2

Signal for solenoid 12

3

Common for solenoid 12 & 14

4

Signal for solenoid 14

3

2

4

1

Pin assignment (acc. VDMA 24571)

11,5

20

53

72,5

92

109

111

113,5

132,5

28

38

52,5

60,5

92,5

81,5

96,5

3

21,5

9,5

19

62,5

19,5

14,5

2

40

N x 19

44

2

25

14,5

N

Number of stations

VALVE ISLAND DIMENSIONS

Electrical connection

Min. no. of valve
stations

Max. no. of valve
stations

Multipole

2

20*

AS-Interface

2

8

Other Fieldbus protocols

4

16

Note: Never plug port 82/84. Plugging this port will
cause valves to malfunction.

Dimensions for surface mounting:
Slot length = 4,3 mm (max. M4 screws).
Clamp length = 35,7 mm.

* For 17 ... 20 station islands please contact your local Norgren technical service