Val- 76, Val ves, V40/v41 mini iso star valves – Norgren V41 Mini ISO Star Valves User Manual

Page 3: 5/3 solenoid pilot actuated valves, Table 1 **voltage codes and spare pilot valves, Table 2 †connector codes and part number

Advertising
background image

V

AL

VES

Norgren.com/usa – 303.794.2611 – [email protected]

VAL-

76

V40/V41 Mini ISO Star Valves

2x3/2, 5/2 and 5/3, Solenoid and Pilot Actuated ISO 15407-1 / VDMA 24 563 Size 18 mm

Model

Spool

Operator

Return

Flow

Operating Pres.

Pilot Pres.

Weight

Repair Kit

Techn.

14

12

Cv

(psig)

(psig)

(lb.)

V405537A-X0090

Gl

Air

Spring

0.58

26" Hg - 232

23.2 - 232

0.24

V70440-K5O

V415537A-X0090

Ss

Air

Spring

0.66

26" Hg - 145

29 - 145

0.22

V70442-K5O

V405533A-X0020

Gl

Air

Air

0.58

26" Hg - 232

29 - 232

0.24

V70441-K5O

V415533A-X0020

Ss

Air

Air

0.66

26" Hg - 145

29 - 145

0.24

V70443-K5O

V405533A-X0020

Gl

Air (priority)

Air

0.58

26" Hg - 232

29 - 232

0.24

V70441-K5O

Model

Function

Actuation

Flow

Operating Pres.

Pilot Pres.

Weight

Spares Kit

2x3/2

3/2 Function

Cv

(psig)

(psig)

(lb.)

V415A33A-X0020

NC

Air/Spring

0.62

0 - 145

24.7 + (0.35 x op. pressure)

0.26

V70447-K5O

V415B33A-X0020

NO

Air/Spring

0.62

0 - 145

24.7 + (0.35 x op. pressure)

0.26

V70448-K5O

V415C33A-X0020

NO/NC

Air/Spring

0.62

0 - 145

24.7 + (0.35 x op. pressure)

0.26

V70449-K5O

2x3/2 Air Pilot Actuated Valves (Softseal Spool)

5/2 Air Pilot Actuated Valves

5 1

3

4

2

10

10

12

14

5 1

3

4

2

14

12

10

10

5 1

3

4

2

10

12

10

14

4

2

14

12

3

5

1

4

2

14

12

3

5

1

4

2

14

12

3

5

1

Model

Spool

Valve

Pilot

Pilot

Operator

Return

Flow

Operating

Pilot Pres.

Weight Repair Kit

Techn.

Function

Supply

Exhaust

14

12

Cv

Pres. (psig)

(psig)

lb.

V405611D-C3**†

Gl

APB

Internal

Collected

Solenoid

Solenoid

0.62

29 - 145

-

0.40

V70441-K5O

V415611D-C3**†

Ss

APB

Internal

Collected

Solenoid

Solenoid

0.69

29 - 145

-

0.40

V70444-K5O

V405622D-C3**†

Gl

APB

External

Not collected

Solenoid

Solenoid

0.62

26" Hg - 232

29 - 145

0.40

V70441-K5O

V415622D-C3**†

Ss

APB

External

Not collected

Solenoid

Solenoid

0.69

26" Hg - 145

29 - 145

0.40

V70444-K5O

V405711D-C3**†

Gl

COE

Internal

Collected

Solenoid

Solenoid

0.62

29 - 145

-

0.40

V70441-K5O

V415711D-C**†

Ss

COE

Internal

Collected

Solenoid

Solenoid

0.69

29 - 145

-

0.40

V70441-K5O

V405722D-C3**†

Gl

COE

External

Not collected

Solenoid

Solenoid

0.62

26" Hg - 232

29 - 145

0.40

V70441-K5O

V415722D-C3**†

Ss

COE

External

Not collected

Solenoid

Solenoid

0.69

26" Hg - 145

29 - 145

0.40

V70445-K5O

V405811D-C3**†

Gl

COP

Internal

Collected

Solenoid

Solenoid

0.62

29 - 145

-

0.40

V70441-K50

V415811D-C3**†

Ss

COP

Internal

Collected

Solenoid

Solenoid

0.69

29 - 145

-

0.40

V70446-K5O

V404822D-C3**†

Gl

COP

External

Not collected

Solenoid

Solenoid

0.62

26" Hg - 232

29 - 145

0.40

V70441-K5O

V415822D-C3**†

Ss

COP

External

Not collected

Solenoid

Solenoid

0.69

26" Hg - 145

29 - 145

0.40

V70446-K5O

5/3 Solenoid Pilot Actuated Valves

4

2

12

14

3

5

1

84

82

4

2

12

14

3

5

1

84

82

4

2

12

14

3

5

1

84

82

4

2

12

14

14

3

5

1

84

82

4

2

12

14

14

3

5

1

84

82

4

2

12

14

14

3

5

1

84

82

Table 1
**Voltage Codes and Spare Pilot Valves

Voltage

Code

Power Inrush / Hold

Pilot Valve Part.-no.

12 V d.c.

12

1.2 W

VZC7L2C1-C312A

24 V d.c.

13

1.2 W

VZC7L2C1-C313A

24 V 50/60 Hz.

14

2.1 / 1.5 VA

VZC7L2C1-C314A

48 V 50/60 Hz

16

2.1 / 1.5 VA

VZC7L2C1-C316A

110 V d.c.

17

1 W

VZC7L2C1-C317A

115 V 50/60 Hz

18

2.1 / 1.5 VA

VZC7L2C1-C318A

230 V 50/60 Hz

19

2.1 / 1.5 VA

VZC7L2C1-C319A

Other voltages available on request.

Spare pilot valves are delivered with mounting screws.

Table 2
†Connector Codes and Part Number

Code Part Number
A = Solenoid without connector
B = Cable grip

V10027-D00

C = 10 ft. molded cable, 0-240 VAC/VDC

V10013-D03

H = Cable grip w/indicator light, 24 VAC/VDC

V10012-D13

J = Cable grip w/indicator light, 120 VAC/VDC

V10012-D18

5 = 10 ft. molded cable with indicator light, surge suppression, 24 VAC/VDC

V10014-D03

6 = 10 ft. molded cable with indicator light, 110V/50 Hz-120V.60Hz

V10015-D03

** Insert voltage code from Table 1 “Voltage Codes and Spare Pilot Valves”.

† Add connector code from Table 2 “Connector Codes and Part Number”.

Advertising