Super x series valves, Val-7-8 – Norgren Super X Series Valves User Manual

Page 8

Advertising
background image

Super X Series Valves

All Dimensions in Inches (mm)

VAL-7-8

Littleton, CO USA

Phone: 303-794-2611

www.norgren.com

03 0409 22
1/8" NPT 3/2 Roller Actuated Pilot Return Valve

.75 (19)

‘12’

‘2’

‘3’

‘1’

1.50 (38)

.20 (5)

‘10’

.87 (22)

3.35 (85)

.87 (22)

1.42 (36)

.18 (5)

1.34 (34)

.83 (21)

.16 (4)

.94 (24)

1/8 NPT

1/8 NPT

.35 (9)

.47 (12)

.39 (10)

.39 (10)

Operating Force: 4 lbs (18N), ‘10’ at zero bar
Reset Pressure: 30 psi (2 bar) minimum
Maximum Recommended Cam Rise: .18" (4.5 mm)
Cam Angle of Approach: 30° maximum
Cam Speed: 26' (8 m)/min. maximum
Operating Speed: 300 cpm

03 0400 22
1/8 NPT 3/2 Plunger Actuated Spring Return Valve

.39 (10)

‘12’

‘2’

‘3’

‘1’

1.50 (38)

.21 (5)

‘10’

.87 (22)

1.42 (36)

.19 (5) max.

1.28 (33)

.83 (21)

.30 (8)

.67 (17)

3.03 (77)

.35 (9)

1/8 NPT

.39 (10)

.75 (19)

Operating Force: 7 lbs (31N)
The plunger on this valve is designed for axial loading only.

03 0417 22
1/8" NPT 3/2 Plunger Actuated Pilot Return Valve

‘12’

‘2’

‘3’

‘1’

‘10’

3.25 (24)

.87 (22)

24

3.25 (83)

1.50 (38)

.19 (5) max.

.39 (10)

.21 (5)

.87 (22)

1.42 (36)

1.28 (33)

.30 (8)

1/8 NPT

.75 (19)

.39 (10)

.35 (9)

.83 (21)

1/8 NPT

Operating Force: 4 lbs (18N), ‘10’ at zero bar
Reset Pressure: 30 lb (2 bar) minimum; Full Movement: 0.19" (4.8mm)
The plunger on this valve is designed for axial loading only. This valve can be
panel mounted.
Panel Cut-out: Ø.59" (15 mm); Panel thickness: 0.2" (5mm)

03 0402 22
1/8" NPT 3/2 Roller Actuated Spring Return Valve

.40 (10)

‘12’

‘2’

‘3’

‘1’

.35 (9)

1.50 (38)

.40 (10)

.21 (5)

‘10’

.67 (17)

3.15 (80)

.87 (22)

1.42 (36)

.18 (5)

.47 (12)

1.34 (34)

.83 (21)

.16 (4)

.75 (19)

1/8 NPT

Operating Force: 7 lbs (31N)
Maximum Recommended Cam Rise: .18" (4.5 mm)
Cam Angle of Approach: 30° maximum
Cam Speed: 26' (8 m)/min. maximum
Operating Speed: 300 cpm

Advertising