background image

82400/82410

824˙˙˙˙.˙˙˙˙.˙˙˙˙˙

N/en 5.8.301.02

03/14

2014-5769c

Our policy is one of continued research and development. We therefore reserve the right to amend,

without notice, the specifications given in this document. © 2014 Buschjost GmbH

Thread form

Substitute

ISO G

0

NPT

1

Port size

Substitute

1/4

0

3/8

1

1/2

2

3/4

3

1

4

1 1/4

5

1 1/2

6

2

7

Valve options

Substitute

Normally open (NO),

from G1 1/4 with solenoid 9151

0,1 ... 16 bar

01

Manual override

02

Seat seal FPM,

Fluid temperature –5 ... +110°C

03

Seat seal EPDM,

for hot water,

max. fluid temperature +110°C

0,3 ... 16 bar (up to G1)

0,3 ... 10 bar (from G1 1/4)

14

Latching system

impuls time min. 30 ms

only for d.c. 6 V, 12 V and 24 V

50

Frequency

Substitute

See table frequency codes

xx

Voltage

Substitute

See Voltage codes

xxx

Solenoid options

Substitute

G1/4 ... 1

Operating pressure

0,1 ... 16 bar

9101

G1 1/4 ... 2

Operating pressure

0,1 ... 10 bar

9101

G1 1/4 ... 2

Operating pressure

0,1 ... 16 bar

9151

Further versions on request!

Standard solenoid systems

Design

DIN VDE 0580

Voltage range

±10%

Duty cycle

100% ED

Protection class

EN 60529 IP65

Socket

Form A acc. to DIN EN 175301-803 (included)

According to DIN VDE 0580 at a solenoid temperature of +20°C.

At operating state temperature the input power of a coil decreases by up to

ca. 30% due to physical reasons.

Electrical details for all solenoid systems

Voltage and Frequency Solenoid 9101 *1)

Code

Voltage

Code

Frequency

Voltage

Frequency

Power consumption
Inrush

Holding

024

00

24 V d.c.

-

8 W

8 W

024

50

24 V a.c.

50 Hz

15 VA

12 VA

110

50

110 V a.c.

50 Hz

15 VA

12 VA

120

60

120 V a.c.

60 Hz

15 VA

12 VA

230

50

230 V a.c.

50 Hz

15 VA

12 VA

Voltage and Frequency Solenoid 9151 *1)

024

00

24 V d.c.

-

18 W

18 W

024

50

24 V a.c.

50 Hz

45 VA

35 VA

110

50

110 V a.c.

50 Hz

45 VA

35 VA

120

60

120 V a.c.

60 Hz

45 VA

35 VA

230

50

230 V a.c.

50 Hz

45 VA

35 VA

ATEX category

Protection class

Solenoid

Standard voltages

II2GD

EEx m II T4 T 130°C

with 3 m connection cable

9136

24 V d.c., 110 V a.c., 230 V a.c.

Attention!
The conditions imposed on the Ex approvals lead to reduction of the permissible

standard temperature ranges in the cases of explosion protected solenoids.

Additional solenoid systems