Norgren F17 Series Installation Instructions User Manual

Installation & maintenance instructions, General purpose filter f17

Advertising
background image

F17

Installation & Maintenance

Instructions

CLEANING
1. Clean mechanical indicator lens (3) with warm water only.

Clean electrical indicator (6) with dry, clean cloth. Clean
other parts with warm water and soap.

2. Rinse and dry parts. Blow out internal passages in body

(34) with clean, dry compressed air. Blow air through filter
element (30) from inside to outside to remove surface
contaminants.

3. Inspect parts. Replace those found to be damaged.

ASSEMBLY
1. Lubricate o-rings with o-ring grease.
2 If the 1/4 turn manual drain (14, 15, 16 ) was removed,

lubricate the portion of the drain body (14) that contacts
the bowl, and the hole in the manual drain body that
accommodates the stem of drain valve (15) with o-ring
grease. Press body (14, ) thru hole from inside of bowl.
Place retainer o-ring (16) over body (14) and position in
groove. Press drain valve (15) thru hole in body (14).

3. Assemble the liquid indicator parts (20, 21, 22, 23, 24, 25)

to bowl. Apply a 0,9 to 1,8 kg (2 to 4 pound) clamping
force to upper and lower brackets (21) to pull brackets
together. Tighten screws (20) to 0,9 to 1,1 N-m (8 to 10
inch-pounds).

4. Assemble filter as shown on the exploded view. Arrows on

indicator (3, 8) and body (34) must point in same
direction. Place o-ring (33) on louver (32), then press in
place into body. Screw baffle (28) onto centerpost until
contact is made with filter element (30).

5. Torque Table

Torque in N-m (Inch-Pounds)

2, 7 (Screw)

2,8 to 3,9 (25 to 35)

18 (Nut), 28 (baffle)

2,3 to 2,8 (20 to 25)

6. Turn bowl (27) into body until arrowhead on bowl is

aligned with or to the right of the arrowhead on the body.

CAUTION
Water vapor will pass through these units and could
condense into liquid form downstream as air temperature
drops. Install an air dryer if water condensation could have a
detrimental effect on the application.

WARNING

These products are intended for use in industrial

compressed air systems only. Do not use these products
where pressures and temperatures can exceed those listed
under Technical Data.

Before using these products with fluids other than air, for

nonindustrial applications, or for life-support systems consult
Norgren.

TECHNICAL DATA
Fluid: Compressed air
Maximum pressure: 17 bar (250 psig)
Operating temperature:* -34° to +80°C (-30° to +175°F)
* Air supply must be dry enough to avoid ice formation at

temperatures below +2°C (+35°F)

Particle removal: 5 µm, 25 µm, 40 µm, or 75 µm filter

element

Air quality: Within ISO 8573-1, Class 3 and Class 5

(particulates)

Typical flow with a 40 µm element at 6,3 bar (90 psig) inlet

pressure and 0,5 bar (7 psid ) pressure drop:
1" ports: 236 dm

3

/s (500 scfm)

Nominal bowl size: 1 litre (1 quart US)
Drain connection: 1/8" pipe thread
Automatic drain operating conditions:

Minimum pressure: 0,7 bar (10 psig).
Drain opens when bowl pressure drops below 0,2 bar

(3 psig).

Minimum air flow required to close drain: 1 dm

3

/s

(2 scfm)

Materials:

Body: Aluminum
Bowl: Aluminum
Bowl sight glass: Pyrex
Elastomers: Neoprene and nitrile
Filter element:

5 µm: Sintered bronze
25 µm: Sintered bronze
40 µm: Sintered bronze
75 µm: Stainless steel screen

REPLACEMENT ITEMS
Service kit (includes items circled on exploded view) ...5778-05
Liquid level lens kit (20, 22 thru26) .........................2273-22
Filter element, 5µm (30) ..........................................5311-01
Filter element, 25µm (30) ........................................5311-02
Filter element, 40µm (30) ........................................5311-03
Filter element, screen, 75µm (30) ............................5656-01
Manual drain (14, 15, 16) ..........................................619-50
Automatic drain (17, 18, 19)....................................3000-10
Mechanical service Indicator (1)..............................5797-50
Electrical service Indicator (6) ...............................4020-51R

INSTALLATION
1. Shut-off air pressure. Install filter in air line -

vertically (bowl down),

with air flow in direction of arrow on body,

upstream of regulators, lubricators, and cycling
valves,

as close as possible to the air supply when used as a
main line filter,

as close as possible to the device being serviced
when used as a final filter.

2. Connect piping to proper ports using pipe thread sealant

on male threads only. Do not allow sealant to enter
interior of unit.

3. Turn bowl (27) into body until arrowhead on bowl is

aligned with or to the right of the arrowhead on the body

4. Flexible tube with 3mm (0.125") minimum I.D. can be

connected to the automatic drain. Avoid restrictions in
the tube.

SERVICING
1. Open manual drain to expel accumulated liquids. Keep

liquids below baffle (28).

2. Clean or replace filter element when dirty, when optional

mechanical service indicator shows approximately all
red, or when optional electrical service indicator provides
an electrical output.

DISASSEMBLY
1. Filter can be disassembled without removal from air line.
2. Shut off inlet pressure. Reduce pressure in inlet and

outlet lines to zero.

3. Disassemble in general accordance with the item

numbers on exploded view.Do not remove the drains or
the service indicators (1, 6) unless replacement is
necessary. Remove and replace only if they malfunction.

© Norgren 2001

2

5

3

4

1

34

33

32

31

30

29

28

13

20

24

25

23

22

16

18

17

15

19

14

21

26

27

23

21

20

6

7

8

9

10

11

12 9A

a subsidiary of IMI plc

IM-341.100

(5/01)

General Purpose Filter

F17 -

★★★ - ★★★★

Thread Form
A....PTF
B....ISO Rc taper
G....ISO G parallel

Port
6 ....3/4"
8 ....1"
A....1-1/4"
B....1-1/2"

Bowl
D...1 litre (1 quart U.S.) metal with sight glass
M ..1 litre (1 quart U.S.) metal without sight glass

Drain
A....Automatic
M...Manual, 1/4 turn

Element
1 ....5µm
2 ....25µm
3 ....40µm
4 ....75µm

Service Indicator
00 ..Without
01 ..With mechanical indicator
04 ..With electrical service indicator

* See Norgren publication IM-900.920 for specifications and electrical wire connections of the optional electric service indicator.