DISASSEMBLY
1. Filter can be disassembled without removal from air line.
2. Shut off inlet pressure. Reduce pressure in inlet and outlet

lines to zero.

3. Disassemble in general accordance with the item numbers

on exploded view. Do not remove the drains unless
replacement is necessary. Remove and replace drains only
if they malfunction.

CLEANING
1. Clean parts with warm water and soap.
2. Rinse and dry parts. Blow out internal passages in body (1)

with clean, dry compressed air.

3. Inspect parts. Replace those found to be damaged.

ASSEMBLY
1. Lubricate seals and o-rings with o-ring grease. Apply a

small amount of anti-seize lubricant to full length of
threads on metal bowl.

2. Assemble filter as shown on the exploded view.
3. Torque Table

Item

Nm

(Inch-Pounds)

6 (retainer)

0,8 to 1,1

(7 to 10)

11, 15, 18 (nut)

2,3 to 2,8

(20 to 25)

24 (baffle)

1,1 to 1,4

(10 to 12)

CAUTION
Do not over torque retainer (6) as damage to gauge glass
(9) will occur.

4. Turn bowl clockwise into body until stop (approximately 5

turns), then unscrew no more than one full turn to position
sight glass for best visibility. Do not attempt to turn bowl
when filter is pressurized.

CAUTION
Water vapor will pass through these units and could
condense into liquid form downstream as air temperature
drops. Install an air dryer if water condensation could have a
detrimental effect on the application.

WARNING

These products are intended for use in industrial

compressed air systems only. Do not use these products
where pressures and temperatures can exceed those listed
under Technical Data.

Do not substitute any other bowl for the stainless steel

bowl furnished with these products.

Before using these products with fluids other than air, for

nonindustrial applications, or for life-support systems consult
Norgren.

TECHNICAL DATA
Fluid: Compressed air
Maximum pressure: 17 bar (250 psig)
Operating temperature: -34° to +80°C (-30° to

+175°F) *

*

Air supply must be dry enough to avoid ice
formation at temperatures below +2°C (+35°F).

Particle removal: 5 µm or 25 µm filter element
Air quality: Within ISO 8573-1, Class 3 and Class 5

(particulates)

Typical flow with 25 µm element at 6,3 bar (90 psig)

inlet pressure, and 0,5 bar (7 psig) pressure
drop: 57 dm

3

/s (120 scfm)

Automatic drain connection:

00 Option: 1/4-18" NPTF
05 and 07 Option: 1/8" - will fit 1/8-27 and 1/8-28

pipe thread

Automatic drain operating conditions (float operated):

Bowl pressure required to close drain: Greater

than 0,3 bar (5 psig)

Bowl pressure required to open drain: Less than

0,2 bar (3 psig)

Minimum air flow required to close drain: 1 dm

3

/s

(2 scfm)

Manual operation: Depress pin inside drain outlet

Nominal bowl size: 0,2 liter (7 fluid ounce)
Materials - Metallic parts are NACE (National

Association of Corrosion Engineers) approved
metals meeting hardness requirements. NACE
Recommendation MR-01-1975 (1980 Revision)
“Material requirement - sulfite stress cracking
resistant metallic material for oil field equipment”.

Body, bowl: Stainless steel
Element: Sintered stainless steel
Elastomers: Nitrile

REPLACEMENT ITEMS
Service kit, auto-drain (items 3, 10, 12, 13, 14,

15, 16, 26, 27, 29)
5 µm element ....................................F22-100A(5)
25 µm element .......................................F22-100A

Service kit, manual drain (items 3, 18, 19, 20,

21, 22, 23, 26, 27, 29)
5 µm element ....................................F22-100M(5)
25 µm element ......................................F22-100M

Bowl repair kit (items 3, 7, 8, 9) ....................5860-RK
Wall mounting bracket ..............................18-001-962

INSTALLATION
1. Shut-off air pressure. Install filter in air line -

vertically (bowl down),

with air flow in direction of arrow on body,

upstream of regulators, lubricators, and cycling valves,

as close as possible to the air supply when used as a
main line filter,

as close as possible to the device being serviced when
used as a final filter.

2. Connect piping to proper ports using pipe thread sealant

on male threads only. Do not allow sealant to enter
interior of unit.

3. Flexible tube with 3 mm (0.125") minimum I.D. can be

connected to the automatic drain. Avoid restrictions in
the tube.

4. Before pressurizing, turn bowl clockwise into body until

stop (approximately 5 turns), then unscrew no more than
one full turn to position sight glass for best visibility.

SERVICING
1. Open manual drain to expel accumulated liquids. Keep

liquids below baffle (24).

2. Replace filter element (26) when dirty or when pressure

drop across element exceeds 0,7 bar (10 psig).

24

1

26

27

28

29

3

5

8

9

8

7

6

4

10

11

12

13

16

14

15

19

20

21

22

23

18

2

17

25

F22

Installation & Maintenance

Instructions

Stainless Steel Filter

F22 -

0- ★★D

Thread Form
A....PTF
D....ISO G
S....Special ported 3/4-16 UNF †

Port
4 ....1/2"
6 ....Special ported

3/4-16 UNF †

Drain
A....Automatic
M...Manual

Element
1 ....5 µm
2 ....25 µm

IM-520.100

(5/02)

Replaces NIP-132

a subsidiary of IMI plc

© Norgren 2002

Option
0 ....1/4" auto drain fitting
5 ....1/8" auto drain fitting or manual drain
7 ....Special ported 3/4-16 UNF equipped with

1/8" auto drain fitting or manual drain †

† Special ported 3/4-16 UNF model: F22-607- x x DS. Drain type and element rating are indicated in positions 7 and 8 of model number.