Norgren B38SS Series Installation Instructions User Manual

B38 (1/4" ported units), Installation & maintenance instructions, Stainless steel instrument regulator b38 - 2

Advertising
background image

B38 (1/4" Ported Units)

Installation & Maintenance

Instructions

ADJUSTMENT

1. Before applying inlet pressure to filter/regulator, turn

adjustment (1) counterclockwise to remove all force on

regulating spring (6).

2. Apply inlet pressure, then turn adjustment (1) clockwise to

increase and counterclockwise to decrease outlet pressure

setting.

3. Always approach the desired pressure from a lower

pressure. When reducing from a higher to a lower setting,

first reduce to some pressure less than that desired, then

bring up to the desired pressure.

NOTE

With non-relieving filter/regulators, make pressure

reductions with some air flow in the system. If made

under no flow (dead-end) conditions, the

filter/regulator will trap the over-pressure in the

downstream line.

4. Tighten locknut (2) to lock pressure setting.
SERVICING

1. Open manual drain to expel accumulated liquids. Keep

liquids below element retainer (28).

2. Replace filter element (30) when dirty (check inner surface

of element), or when pressure drop across element

exceeds 0,7 bar (10 psig).

DISASSEMBLY

1. Filter/regulator can be disassembled without removal from

air line.

2. Shut off inlet pressure. Reduce pressure in inlet and outlet

lines to zero.

3. Turn adjustment screw (1) fully counterclockwise.

4. Disassemble in general accordance with the item numbers

on exploded view. Do not remove the drains unless

replacement is necessary. Remove and replace drains only

if they malfunction.

CLEANING

1. Clean parts with warm water and soap.

2. Rinse and dry parts. Blow out internal passages in body

(31) with clean, dry compressed air.

3. Inspect parts. Replace those found to be damaged.
ASSEMBLY

1. Lubricate threads of adjusting screw (1), recess of upper

sprint rest (5), and o-rings with a light coat of good quality

o-ring grease.

2. Assemble the unit as shown on the exploded view.

Assemble bonnet (4) to body (31) so that relief hole is

above outlet port.

3. Torque Table

Item

Nm

(Inch-Pounds)

3, 15, 21 (screws)

3,3 to 7,3 (30 to 66)

28 (element retainer)

1,3 to 1,7 (12 to 15)

CAUTION

Water vapor will pass through these units and could

condense into liquid form downstream as air temperature

drops. Install an air dryer if water condensation could have a

detrimental effect on the application.
WARNING

These products are intended for use in industrial

compressed air systems only. Do not use these products

where pressures and temperatures can exceed those listed

under Technical Data.

If outlet pressure in excess of the regulator pressure

setting could cause downstream equipment to rupture or

malfunction, install a pressure relief device downstream of

the regulator. The relief pressure and flow capacity of the

relief device must satisfy system requirements.

The accuracy of the indication of pressure gauges can

change, both during shipment (despite care in packaging)

and during the service life. If a pressure gauge is to be used

with these products and if inaccurate indications may be

hazardous to personnel or property, the gauge should be

calibrated before initial installation and at regular intervals

during use.

Before using these products with fluids other than air, for

non industrial applications, or for life-support systems

consult Norgren.

TECHNICAL DATA

Fluid: Compressed air

Maximum pressure:

Manual drain: 31 bar (450 psig)

Automatic drain: 17 bar (250 psig)

Operating temperature: -40° to +80°C (-40° to +175°F)*

* Air supply must be dry enough to avoid ice formation

at temperatures below +2°C (+35°F).

Particle removal: 5 µm or 25 µm filter element

Air quality: Within ISO 8573-1, Class 3 and Class 5

(particulates)

Typical flow with 12 bar (175 psig) inlet pressure, 8 bar

(115 psig) set pressure and a droop of 1,0 bar (15

psig) from set: 7 dm

3

/s (15 scfm)

Maximum bleed flow at 2 bar (30 psig) outlet pressure

(relieving models only): 1,5 cm

3

/s (0.003 scfm)

Automatic drain connection: 1/4-18" NPTF

Automatic drain operating conditions (float operated):

Bowl pressure required to close drain: Greater than

0,3 bar (5 psig)

Bowl pressure required to open drain: Less than

0,2 bar (3 psig)

Minimum air flow required to close drain:1 dm

3

/s

(2 scfm)

Manual operation: Depress pin inside drain outlet

Nominal bowl size:

Short bowl with manual drain: 25 ml (1 fluid oz)

Long bowl with automatic drain: 25 ml (1 fluid oz)

Gauge ports: 1/4", thread form same as main ports

Relief port: 1/8", thread form same as main ports

Materials:

Body, bonnet, bowl, adjusting screw: Stainless steel

Elements:

5 µm: Stainless steel

25 µm: High density polyethylene

Elastomers: Nitrile

SERVICE KITS

Regulator - items 3, 7, 11, 12, 15, 21, 27

Relieving, 2 bar spring ..........................................R38-100R

Relieving, 4 and 7 bar spring ................................R38-101R

Relieving, 10 bar spring ........................................R38-102R

Non-relieving, 2 bar spring .................................R38-100NR

Non-relieving, 4 and 7 bar spring .......................R38-101NR

Non-relieving, 10 bar spring ...............................R38-102NR

Filter - items 3, 17, 18, 19, 27, 30

Filter, 5 µm element...........................................B38-100S(5)

Filter, 25 µm element.......................................B38-100S(25)

PANEL MOUNTING DIMENSIONS

Panel mounting hole diameter: 42 mm (1.65")

Maximum panel thickness: 6 mm (0.24")
INSTALLATION

1. Shut off air pressure. Install filter/regulator in air line -

!

vertically (bowl down),

!

with air flow in direction of arrow on body. In some cases

IN

is stamped next to the inlet port.

!

upstream of lubricators and cycling valves,

!

as close as possible to the device being serviced.

2. Connect piping to proper ports using pipe thread sealant on

male threads only. Do not allow sealant to enter interior.

3. Flexible tube with 3mm (0.125") minimum I.D. can be

connected to the automatic drain. Avoid restrictions in the

tube.

4. Install a pressure gauge or plug the gage ports. Gage ports

can also be used as additional outlets for regulated air.

© Norgren 2002

IM-510.315.01

(3/02)

Supersedes (1/99)

* Outlet pressure can be adjusted to pressures in excess of, and less than, those specified. Do not use these units to control pressures outside of the specified ranges.

Stainless Steel

Instrument Regulator

B38 - 2"" - """"

Material

4....Stainless steel with Nitrile

elastomers

5....Stainless steel with Viton

elastomers

Port

2....1/4"

Spring (Outlet Pressure Range) *

C....0,1 to 2 bar (1 to 30 psig)

F ....0,1 to 4 bar (1 to 60 psig)

K....0,3 to 7 bar (5 to 100 psig)

M...0,3 to 10 bar (5 to 150 psig)

Thread Form

A....PTF

B....ISO Rc

D....ISO G

Bowl/Drain

A....Long bowl/auto drain

B....Short bowl/manual drain

Element

1 .......5 µm

2 .......25 µm

Diaphragm

0....Relieving

1....Non-relieving

2....Relieving with wall bracket and panel nut

3....Non-relieving with wall bracket and panel nut

4....Relieving with panel nut

5....Non-relieving with panel nut