Norgren B38SS Series Datasheets User Manual

Norgren Hardware

Advertising
background image

See Section ALE-24 for Accessories

ALE-16-12

Littleton, CO USA

Phone 303-794-2611

www.norgren.com

B38

Compact instrument units with high performance

Stable regulation with temperature compensation

Excellent flow and regulation characteristics

Panel Mounting facility

Designed for use in corrosive environments

Metallic parts meet NACE Standard MR-01-75*

Applications include marine environments, oil and

gas production, chemical and food processing,
medical analysis

Relieving or non relieving models. Relieving models

allow reduction of outlet pressure even when the
system is dead-ended

* National Association of Corrosion Engineers (NACE) MR-01-75 defines requirements for
sulphide stress cracking resistant materials used in well-head and other corrosive environments.

Filter/Regulator Stainless Steel Model

1/4 or 1/2” PTF

ISO Symbols

Automatic Drain, Relieving

Automatic Drain, Non Relieving

Manual Drain, Relieving

Manual Drain, Non Relieving

Outlet pressure range

Port Size

Model Number

psig (bar)

Flow** scfm (dm

3

/s)

Weight kg (lbs)

1/4” PTF

B38-240-B1KA

4 to 100 (0.3 to 7)

15 (7)

3.11 (1.4)

1/2” PTF

B38-440-M1LA

4 to 125 (0.3 to 9)

106 (50)

4.75 (2.2)

Ordering Information.

Models listed are relieving type with manual drain, 5µm element, and PTF threads. A gauge is not included.

** Typical flow with 175 psig (12 bar) inlet pressure, 115 psig (8 bar) set pressure and 15 psig (1 bar) droop from set.

Alternative Models

Port Size

Substitute

1/4” PTF

2

1/2” PTF

4

Materials

Substitute

Stainless steel, nitrile elastomers

4

Stainless steel, Viton elastomers

5 †

Threads

Substitute

PTF

A

ISO Rc taper

B

ISO G parallel

D

API.LP.INT

K

Outlet Pressure Adjustment Ranges* Substitute
0.6 to 30 psig (0.04 to 2 bar)

C

1 to 60 psig (0.07 to 4 bar)

F

3.6 to 100 psig (0.25 to 7 bar)

K †

4 to 125 psig (0.3 to 9 bar)

L ††

7.2 to 150 psig (0.5 to 10 bar)

M †

Element

Substitute

5 µm

1

25 µm

2

Bowl/Drain

Substitute

Long bowl with automatic drain

A

Short bowl with manual drain

B

Long bowl with manual drain

M

*

Outlet pressure can be adjusted to pressures in excess of, and less than, those specified.
Do not use these units to control pressures outside of the specified ranges.

1/4” ported units only.

†† 1/2” ported units only.

8

3

B

★ ★ ★ ★ ★ ★ ★

-

-

Diaphragm

Substitute

Relieving

0

Non relieving

1

Relieving, bracket and nut

2

Non relieving, bracket and nut

3

Relieving with nut

4

Non relieving with nut

5

Relieving with handwheel and nut

6

Non relieving with handwheel and nut

7

Relieving with handwheel, bracket and nut

8

Non relieving with handwheel, bracket and nut

9

Advertising