See Section ALE-24 for Accessories

ALE-16-12

Littleton, CO USA

Phone 303-794-2611

www.norgren.com

B38

● Compact instrument units with high performance

● Stable regulation with temperature compensation

● Excellent flow and regulation characteristics

● Panel Mounting facility

● Designed for use in corrosive environments

● Metallic parts meet NACE Standard MR-01-75*

● Applications include marine environments, oil and

gas production, chemical and food processing,
medical analysis

● Relieving or non relieving models. Relieving models

allow reduction of outlet pressure even when the
system is dead-ended

* National Association of Corrosion Engineers (NACE) MR-01-75 defines requirements for
sulphide stress cracking resistant materials used in well-head and other corrosive environments.

Filter/Regulator Stainless Steel Model

1/4 or 1/2” PTF

ISO Symbols

Automatic Drain, Relieving

Automatic Drain, Non Relieving

Manual Drain, Relieving

Manual Drain, Non Relieving

Outlet pressure range

Port Size

Model Number

psig (bar)

Flow** scfm (dm

3

/s)

Weight kg (lbs)

1/4” PTF

B38-240-B1KA

4 to 100 (0.3 to 7)

15 (7)

3.11 (1.4)

1/2” PTF

B38-440-M1LA

4 to 125 (0.3 to 9)

106 (50)

4.75 (2.2)

Ordering Information.

Models listed are relieving type with manual drain, 5µm element, and PTF threads. A gauge is not included.

** Typical flow with 175 psig (12 bar) inlet pressure, 115 psig (8 bar) set pressure and 15 psig (1 bar) droop from set.

Alternative Models

Port Size

Substitute

1/4” PTF

2

1/2” PTF

4

Materials

Substitute

Stainless steel, nitrile elastomers

4

Stainless steel, Viton elastomers

5 †

Threads

Substitute

PTF

A

ISO Rc taper

B

ISO G parallel

D

API.LP.INT

K

Outlet Pressure Adjustment Ranges* Substitute
0.6 to 30 psig (0.04 to 2 bar)

C

1 to 60 psig (0.07 to 4 bar)

F

3.6 to 100 psig (0.25 to 7 bar)

K †

4 to 125 psig (0.3 to 9 bar)

L ††

7.2 to 150 psig (0.5 to 10 bar)

M †

Element

Substitute

5 µm

1

25 µm

2

Bowl/Drain

Substitute

Long bowl with automatic drain

A

Short bowl with manual drain

B

Long bowl with manual drain

M

*

Outlet pressure can be adjusted to pressures in excess of, and less than, those specified.
Do not use these units to control pressures outside of the specified ranges.

†

1/4” ported units only.

†† 1/2” ported units only.

8

3

B

★ ★ ★ ★ ★ ★ ★

-

-

Diaphragm

Substitute

Relieving

0

Non relieving

1

Relieving, bracket and nut

2

Non relieving, bracket and nut

3

Relieving with nut

4

Non relieving with nut

5

Relieving with handwheel and nut

6

Non relieving with handwheel and nut

7

Relieving with handwheel, bracket and nut

8

Non relieving with handwheel, bracket and nut

9

Advertising