Norgren B38P Series User Manual

Technical features, B38p-˙˙˙-˙˙m˙ option selector

Advertising
background image

N/en 8.530.350.01

B38P

High flow filter/regulator (stainless steel)

1/4 NPT, 3/8 NPT, G1/4 or G3/8

Our policy is one of continued research and development. We therefore reserve the right to amend,

without notice, the specifications given in this document. © 2014 Norgren China

7/14

2011-8168d

High flow filter/regulator designed for

use in corrosive environment
Metallic parts meet NACE* Standard MR-01-75
Applications include marine environment,

oil and gas productions

* National Association of Corrosion Engineers – recognised oil-field recommendation for

resistance to sulphide stress cracking common in well-head and other corrosive environments

Medium:
Compressed air only

Maximum inlet pressure:
31 bar (manual drain)
17 bar (autodrain)

Outlet pressure range:
0,5 ... 10 bar

Flow:
40 dm

3

/s

Element:
5, 25 or40 μm

Port sizes:
1/4 NPT, 3/8 NPT, G1/4 or G3/8
1/4 PTF (gauge) and
1/4 NPT (automatic drain)

Drain:
Manual or automatic
Automatic drain operation
conditions (float operated):

To close: > 0,3 bar,
To open: < 0,2 bar
Minimum air flow required to
close 1 dm

3

/s

Ambient/Media temperature:
-20 ... +80°C (FPM seals)
-40 ... +80°C (NBR seals)
Air supply must be dry enough
to avoid ice formation at
temperatures below +2°C.

Technical features

Materials:
Body, bowl, bonnet, filter element
and adjusting screw:
316 stainless steel
Elastomers: FPM or NBR

Technical data, standard model, relieving and panel nut

Symbol

Port size Outlet pressure *1)

(bar)

Element

(μm)

Flow *2)

(dm

3

/s)

Drain

Weight

(kg)

Model

1/4 NPT 0,5 ... 10

5

40

Manual

1,61

B38P-254-B1MA

3/8 NPT

0,5 ... 10

5

40

Manual

1,60

B38P-354-B1MA

1/4 NPT 0,5 ... 10

5

40

Automatic

1,74

B38P-254-A1MA

3/8 NPT 0,5 ... 10

5

40

Automatic

1,73

B38P-354-A1MA

*1) Outlet pressure can be adjusted to pressures in excess of, and less than,

those specified. Do not use these units to control pressures outside of the

specified ranges.

*2) Typical flow with 10 bar inlet pressure, 6,3 bar set pressure and a 1 bar drop

from set.

B38P-˙˙˙-˙˙M˙

Option selector

Port size *

Substitute

1/4”

2

3/8”

3

Temperature range

Substitute

-20 ... +80°C (FPM seals)

5

-40 ... +80°C (NBR seals)

4

Bracket

Substitute

Inclusive

2

Without

4

* 1/2” port size on request

Thread form

Substitute

NPT

A

ISO G parallel

G

Element

Substitute

5 µm

1

25 µm

2

40 µm

3

Drain

Substitute

Automatic

A

Manual short bowl

B

Advertising