076 lubricators, Ale-14-19, Technical data – Norgren Lubricators User Manual

Page 23: Typical performance characteristics, Service kits

Advertising
background image

10-076 Lubricators

ALE-14-19

All Dimensions in Inches (mm)

Littleton, CO USA

Phone 303-794-2611

Fax 303-795-9487

Technical Data

Fluid: Compressed air
Maximum pressure: 250 psig (17 bar)
Operating temperature*: 0° to 175°F (-20° to 80°C)

* Air supply must be dry enough to avoid ice formation at temperatures below 35°F (2°C).

Start point (minimum flow required for lubricator operation) at 90 psig (6.3 bar)

inlet pressure: 240 scfm (123 dm

3

/s)

Typical flow with 90 psig (6.3 bar) inlet pressure and 5 psig (0.35 bar) pressure

drop: 1300 scfm (614 dm

3

/s)

Nominal reservoir sizes:

2 U.S. gallon (8 liter)
5 U.S. gallon (20 liter)

Recommended lubricants: See Section ALE-29.
Materials

Body and adapter: Aluminum
Reservoir: Steel
Reservoir liquid level indicator lens: Pyrex
Sight-feed dome

Standard: Transparent nylon
Optional: Pyrex and aluminum

Elastomers: Nitrile

16

12

8

4

0

INLET PRESSURE

bar

240

200

160

120

80

40

0

psig

0

200

400

600

800

1000

dm

3

/s

AIR FLOW

0

400

800

1200

1600

2000

scfm

OPERATING RANGE

A

B

A: Minimum flow based on oil drip rate of 5 drops per minute.
B: Maximum flow based on pressure drop of 5 psid (0.35 bar).

Oil: SAE 10
Oil Feed Setting: Maximum

Typical Performance Characteristics

Reservoir

A

B

C

D

2 gallon (8 liter)

7.81 (198)

7.18 (182)

21.53 (547)

35 (887)

5 gallon (20 liter)

11.81 (300) 11.18 (284) 24.78 (629)

40 (1014)

C

5.13 (130)

2.31

(59)

2 and 5 gallon (8 and 20 liter) reservoir

** Optional pyrex sight-feed dome.
† Minimum clearance required to remove bowl.

D

A

B

3.15

(80)**

Reservoir sight glass kits include sight glass, sight glass guards,
seals, and hardware.

Service Kits

Item

Type

Part Number

Liquid level lens kit

8 and 20 liter reservoir

2274-01

Replacement drain

Manual petcock

684-01

Advertising