Norgren R83 Series User Manual

Norgren Hardware

Advertising
background image

See Section ALE-24 for Accessories

ALE-10-4

Littleton, CO USA

Phone 303-794-2611

www.norgren.com

R83

Underwriters Laboratories, Inc. listed (file number
SA1089) for use with air, argon, carbon dioxide,
helium, krypton, neon, nitrogen, xenon. For use with
other gases, including oxygen, consult Norgren.

Non-relieving and relieving models. Relieving models
allow reduction of outlet pressure even when the
system is dead-ended

Two high pressure inlet ports and two regulated
pressure outlet ports

Diametrically opposite inlet ports provide easy
manifolding of several regulators

Easily replaceable valve cartridge contains valve,
valve seat, valve spring, and filter element

UL Listed Pressure Regulator for

Industrial Cylinder Gas 1/4" PTF Port Size

Ordering Information.

Models listed include PTF threads, relieving diaphragm, 5 to 125 psig (0.3 to 8.5 bar) outlet pressure adjustment

range

, and without gauge.

Port

Model

Flow * scfm dm

3

/s()

Weight lb (kg)

1/4"

R83-200-RNLA

11 (5.2)

1.3 (0.59)

Alternative Models

-

A

N

2 0

-

8

0

R

3

Outlet Pressure Adjustment Ranges

Substitute

2 to 50 psig (0.1 to 3.5 bar)

E

5 to 125 psig (0.3 to 8.5 bar)

L

10 to 175 psig (0.7 to 12 bar)

N

Diaphragm

Substitute

Relieving

R

Non relieving

N

*

Approximate flow with 1000 psig (69 bar) inlet pressure, 60 psig (4 bar) set pressure and a 5 psig (0.35 bar) droop from set.

Outlet pressure can be adjusted to pressures in excess of, and less than, those specified. Do not use these units to control pressures outside of the specified ranges.

Advertising