Norgren 11-008 Series Datasheets User Manual

Norgren Hardware

Advertising
background image

See Section ALE-24 for Accessories

ALE-9-4

Littleton, CO USA

Phone 303-794-2611

www.norgren.com

11-008

Designed for systems that require pressure
regulation at an inaccessible location.

A pilot regulator (ordered separately) controls the
outlet pressure of the pilot operated regulator.

For general purpose applications, order an R72 or
R07 pilot regulator.

For precision applications, order an R40, R41, or 11-
104 pilot regulator.

Constant bleed feature provides quick maximum
sensitivity to system changes

Pilot Operated Regulator

1/2", 3/4" and 1" Port Sizes

ISO Symbols

With Conventional

Pilot Regulator

With Feedback
Pilot Regulator

Alternative Models

Threads

Substitute

PTF

0

ISO G parallel

8

ISO G Rc

9

1

1

0 8

★ ★ ★

-

-

Pilot Operated Regulator Ordering Information

Models listed include relieving diaphragm and PTF threads. Also order a pilot regulator.

Port Size

Model

Flow

*

scfm (dm

3

/s)

Weight lb (kg)

1/2"

11-008-130

70 (33)

1.6 (0.7)

3/4"

11-008-009

110 (52)

4.9 (2.2)

1"

11-008-110

180 (85)

4.6 (2.1)

* Typical flow with a conventional pilot at 150 psig (10.3 bar) inlet pressure, 100 psig (6.9 bar) set pressure and a droop of less than 5 psig (0.35 bar) from set.

With 150 psig (10 bar) Gauge

Substitute

1/2" main ports

142

3/4" main ports

021

1" main ports

122

Feedback Pilot Regulator Warning

The feedback line must sense the pilot operated regulator outlet pressure
and must be connected before turning on the air supply. If the feedback line
is not connected, the pilot operated regulator outlet pressure will rapidly
increase to the inlet pressure when the adjusting knob on the pilot
regulator is turned clockwise.