Norgren R41 Series Datasheets User Manual

R40, r41

Advertising
background image

See Section ALE-24 for Accessories

ALE-8-2

Littleton, CO USA

Phone 303-794-2611

www.norgren.com

R40, R41

Pilot regulators are used to control the outlet
pressure of a pilot operated regulator (ordered
separately)

The pilot regulator is installed in an accessible
location in the compressed air system; pilot operated
regulator is installed at any point without regard to
accessibility

Conventional pilot regulator provides good pressure
regulation, rapid response to changing flow
demands, and excellent stability.

Feedback pilot regulator provides superior pressure
regulation under changing flow demands where
changes in flow demand are not sudden or cyclic.

Constant bleed feature provides maximum sensitivity
to system changes

Relief feature allows reduction of downstream
pressure when the system is dead-ended

R40 Conventional Pilot Regulator

R41 Feedback Pilot Regulator

1/4" Port Size

ISO Symbols

R40 Conventional Pilot Regulator

with Pilot Operated Regulator

R41 Feedback Pilot Regulator

with Pilot Operated Regulator

Ordering Information.

Models listed are relieving with constant bleed, 10 to 250 psig (0.7 to 17 bar) outlet pressure adjustment range

*

, PTF ports.

Alternative Models

-

N

B

2

-

R

Threads

Substitute

PTF

A

ISO Rc taper

B

ISO G parallel

G

Type

Substitute

R40 Conventional

40

R41 Feedback

41

Mounting/Type

Substitute

Remote/R40 Conventional

00

Remote/R41 Feedback

04

Outlet Pressure Adjustment Ranges*

Substitute

2 to 50 psig (0.1 to 3.5 bar) R40 only

E

5 to 125 psig (0.3 to 8.5 bar) R40 only

L

10 to 250 psig (0.7 to 17 bar)

S

Port Size

Type

Model

Flow

scfm (dm

3

/s)

Weight lb (kg)

1/4"

Conventional Pilot

R40-200-BNSA

6.4 (3)

1.66 (0.75)

1/4"

Feedback Pilot

R41-204-BNSA††

6.4 (3)

1.66 (0.75)

† Typical flow with 100 psig (7 bar) inlet pressure, 90 psig (6.3 bar) set pressure and 15 psig (1 bar) droop from set.

†† Do not use the R41 feedback pilot regulator to control outlet pressures at or less than 100 psig (7 bar). Use the 11-104 feedback pilot regulator at those pressures.

* Outlet pressure can be adjusted to pressures in excess of, and less than, those specified. Do not use

these units to control pressures outside of the specified ranges.

Feedback Pilot Regulator Warning

The feedback line must sense the pilot operated regulator outlet pressure
and must be connected before turning on the air supply. If the feedback line
is not connected, the pilot operated regulator outlet pressure will rapidly
increase to the inlet pressure when the adjusting knob on the pilot regulator
is turned clockwise.