P74f smooth start/exhaust valve, Ale-17-9, Technical data – Norgren P72F Series Datasheets User Manual

Page 4: Typical performance characteristics

Advertising
background image

P74F Smooth Start/Exhaust Valve

Littleton, CO USA

Phone 303-794-2611

www.norgren.com

ALE-17-9

All Dimensions in Inches (mm)

Technical Data

System air supply: Turn on system air supply prior to applying pilot signal to operator.

Failure to do so may cause valve to continuously exhaust.

Fluid: Compressed air
Maximum pressure solenoid operated:

Dependant on solenoid rating
[must not exceed 250 psig (17 bar)]

Maximum pressure pilot operated: 250 psig (17 bar) max.
Minimum operating pressure: 44 psig (3 bar)
Operating temperature solenoid operated:

Dependant on solenoid rating
[must be within range 0°* to 175°F (-20°* to 80°C)]

Operating temperature pilot operated:

0°* to 175°F (-20°* to 80°C)

* Air supply must be dry enough to avoid ice formation at temperatures below 35

°

F (2

°

C).

Air pilot port:

ISO Rc1/4 with ISO Rc main ports
ISO Rc1/4 with ISO G main ports
1/4PTF with PTF main ports

Exhaust port:

ISO G1/2 with ISO G main ports
ISO G1/2 with ISO Rc main ports
1/2PTF with PTF main ports

Typical flow with 90 psig (6.3 bar) inlet pressure and pressure drop of 7 psig (0.5 bar):

57 dm

3

/s (P1 to P2 = Cv 4.4) (P2 to P3 = Cv 5.6)

Snap pressure:

Full flow when downstream pressure reaches 50 – 80% of inlet pressure

Charge time:

For 2 liter downstream volume and 90 psig (6.3 bar) inlet pressure:
0.2 sec. minimum
76 sec. maximum

Materials

Body: Aluminium
Intermediate body: Aluminium
Elastomers: Synthetic materials
Filter discs: Sintered plastic
Internal components: Brass/steel
Top plate: Zinc
Exhaust bonnet: Zinc

Typical Performance Characteristics

INLET PRESSURE: psig (bar g)

FLOW CHARACTERISTICS

0 20 40 60 80 100

dm

3

/s

AIR FLOW

0 40 80 120

160

200

240

scfm

0.8

0.6

0.4

0.2

0

PRESSURE DROP

bar d

10

8

6

4

2

0

psid

PORT SIZE: 1/2"

44

(3)

91

(6.3)

58

(4.0)

116

(8)

150

(10)

2 quart (2 liter) downstream volume

PERCENTAGE SNAP POINT

0 20 40 60 80 100

120

CHARGE TIME - (S)

16

12

8

4

0

OUTLET PRESSURE

bar g

200

160

120

80

40

0

psig

SNAP POINT

8.35 (212)

6.14 (156)

1/2 PTF (G1/2)

1.18 (30) A/F

3.31 (84)

2.91 (74)

1.46 (37)

1/2 PTF (G1/2)

1.18 (30) A/F

5.67 (144)

3.46 (88)

1/4 PTF (Rc1/4)

3.31 (84)

2.91 (74)

1.46 (37)

8.70 (221)

6.50 (165)

3.31 (84)

4.37 (111) max.

3.78 (96) min.

1.46 (37)

1/2 PTF (G1/2)

1.18 (30) A/F

6.38 (162)

4.21 (107)

1/4 PTF (Rc1/4)

3.31 (84)

4.37 (111) max.

3.78 (96) min.

1.46 (37)

1/2 PTF (G1/2)

1.18 (30) A/F

Solenoid operated

Solenoid operated plus

manual shut-off with lockout

Air pilot operated

Air pilot operated plus

manual shut-off with lockout

Advertising