T72 shut-off & lockout valves – Norgren T72 Series Datasheets User Manual
Page 2
T72 Shut-off & Lockout Valves
Littleton, CO USA
Phone 303-794-2611
www.norgren.com
ALE-15-3
All Dimensions in Inches (mm)
Technical Data
Fluid: Compressed air
Maximum Pressure: 250 psig (17 bar)
Operating Temperature*: -30° to 150°F (-34° to 65°C)
* Air supply must be dry enough to avoid ice formation at temperatures below 35°F (2°C).
Cv factor from IN to OUT ports
1/4" ports: 4.0
3/8" ports: 8.0
Cv factor from OUT to EXHAUST ports on 3-port/2-position valves: 0.2.
Exhaust port threads on T72T models: 10-32
Hole diameter in slide for padlock: 5/16" (8 mm)
Materials
Body: Zinc
Slide: Acetal plastic
Elastomers: Nitrile
Service Kits
Item
Type
Part Number
Service kit
Actuator seals and slide
4384-513
Service kit includes actuator seals and slide.
1.97 (50)
1.89 (48)
3.46 (88)