Mapping a network drive for backups, Setting up user accounts for network backups – Lenovo ThinkPad R61i User Manual

Page 32

Advertising
background image

Mapping a network drive for backups

The map network drive function relies on the registry settings located at
HKLM\Software\Lenovo\MND.

The Universal Naming Convention entry contains the computer name and share of
the location you are attempting to attach.

The NetPath entry is output from the mapdrv.exe. It contains the actual name
which was used when making the connection.

User and Pwd entries are the username and password entries. They are encrypted.

The following is an example entry for mapping a network drive:

UNC=\\server\share

NetPath=\\9.88.77.66\share

User=11622606415119207723014918505422010521006401209203708202015...

Pwd=11622606415100000000014918505422010521006401209203708202015...

For deployment, this file can be copied onto multiple computers that will use the
same user name and password. The UNC entry is overwritten by Rescue and
Recovery based on a value in the rnrdeploy.xml file.

Setting up user accounts for network backups

When the RRBACKUPS directory is created on the network share, the service
makes the directory a read-only folder, and assigns it access rights so that only the
account that created the folder has full control over the folder.

To complete a merge operation, MOVE permissions exist for the User account. If
logged in with an account other than the account that created the folder initially,
such as the administrator, the merge process will fail.

Capturing a Sysprep utility image in the base backup

These instructions are for the files that can be downloaded separately for the: Large
Enterprise individual language
files that you can download from the Lenovo Web
site:
http://www.lenovo.com/support

To capture a Sysprep utility image in the base backup, do the following:
1.

Perform an administrative installation:

:: Extract the WWW EXE to the directory C:\TVTRR
start /WAIT z652zisxxxxus.exe /a /s /v"/qn TARGETDIR
(Where XXXX is the build ID.)
="C:\TVTRR" REBOOT="R"" /w

2.

Install Rescue and Recovery using the MSIEXE file:
a.

For all MSI files, add the following installation-log generation code:

/L*v %temp%\rrinstall.txt

b.

To install the setup files using the MSIEXE file, enter the following
command:

: Perform the install of Rescue and Recovery

msiexec /i "C:\TVTRR\Rescue and Recovery.msi"

c.

To silently install the setup files using MSIEXE:
With reboot at the end, enter the following command:

24

Rescue and Recovery 4.21 Deployment Guide

Advertising