Microprocessors:

v

Supports

up

to

two

Intel

®

Xeon

®

dual-core

processors

v

4

MB

shared

Level-2

cache

v

667,

1066,

or

1333

MHz

front-side

bus

(FSB)

Note:

Use

the

Configuration/Setup

Utility

program

to

determine

the

type

and

speed

of

the

microprocessors.

Memory:

v

Minimum:

1

GB

v

Maximum:

32

GB

(16

GB

in

mirrored

mode)

v

Type:

PC2-5300,

ECC

fully-buffered

with

double-data-rate

2

(DDR2)

SDRAM

v

Connectors:

eight

dual

inline

memory

module

(DIMM)

connectors,

two-way

interleaved

Drives

(depending

on

the

model):

v

Diskette

(optional):

External

USB

diskette

drive

v

Hard

disk

drive:

SATA

v

One

of

the

following

IDE

drives:

CD-ROM

CD-RW

(optional)

DVD-ROM

(optional)

DVD-ROM/CD-RW

(optional)

Expansion

bays

(depending

on

the

model):

v

Three

half-high

5.25-in.

bays

(one

CD

or

DVD

drive

installed)

or

one

half-high

CD

or

DVD

drive

and

one

full-high

tape

drive

v

Four

3.5-in.

simple-swap

bays

PCI

expansion

slots

(depending

on

the

model):

v

Six

PCI

expansion

slots

Three

PCI

Express

x8

slots

(two

x8

links

and

one

x4

link)

One

PCI

32-bit/33

MHz

slot

Two

PCI-X

64-bit/133

MHz

slots

Fans:

Three

speed-controlled

hot-swap

fans

Power

supply:

670

watt

(90-240

V

ac)

Size:

v

Height:

440

mm

(17.3

in.)

v

Depth:

747

mm

(29.4

in.)

v

Width:

218

mm

(8.6

in.)

v

Weight:

20

kg

(42

lb)

to

34

kg

(75

lb)

depending

upon

configuration

Integrated

functions:

v

Baseboard

management

controller

(BMC)

or

onboard

service

processor

v

Broadcom

5721

10/100/1000

Ethernet

controller

on

the

system

board

with

RJ-45

Ethernet

port

v

Six-port,

Serial

ATA

controller

v

Integrated

RAID

capability

(HostRAID)

v

Two

serial

ports

v

One

parallel

port

v

Four

Universal

Serial

Bus

(USB)

v2.0

ports

(two

on

front

and

two

on

rear)

v

Keyboard

port

v

Mouse

port

v

ATA-100

single-channel

IDE

controller

(bus

mastering)

v

ATI

ES1000

video

controller

Compatible

with

SVGA

and

VGA

16

MB

SDRAM

video

memory

Diagnostic

LEDs:

v

Fans

v

Memory

v

Power

supply

Acoustical

noise

emissions:

v

Sound

power,

idling:

5.6

bel

v

Sound

power,

operating:

6.0

bel

Environment:

v

Air

temperature:

Server

on:

10°

to

35°C

(50°

to

95°F)

Altitude:

0

to

914

m

(2998.0

ft)

Server

off:

-40°

to

60°C

(-40°

to

140°F)

Altitude:

0

to

2133

m

(7000.0

ft)

v

Humidity

(operating

and

storage):

8%

to

80%

Heat

output:

Approximate

heat

output

in

British

thermal

units

(Btu)

per

hour:

v

Minimum

configuration:

693

Btu

per

hour

(203

watts)

v

Maximum

configuration:

1631

Btu

per

hour

(478

watts)

Electrical

input:

v

Sine-wave

input

(50

or

60

Hz)

required

v

Input

voltage

and

frequency

ranges

automatically

selected

v

Input

voltage

low

range:

Minimum:

100

V

ac

Maximum:

127

V

ac

v

Input

voltage

high

range:

Minimum:

200

V

ac

Maximum:

240

V

ac

v

Input

kilovolt-amperes

(kVA)

approximately:

Minimum:

0.21

kVA

(all

models)

Maximum:

0.49

kVA

Notes:

1.

Power

consumption

and

heat

output

vary

depending

on

the

number

and

type

of

optional

features

installed

and

the

power-management

optional

features

in

use.

2.

These

levels

were

measured

in

controlled

acoustical

environments

according

to

the

procedures

specified

by

the

American

National

Standards

Institute

(ANSI)

S12.10

and

ISO

7779

and

are

reported

in

accordance

with

ISO

9296.

Actual

sound-pressure

levels

in

a

given

location

might

exceed

the

average

values

stated

because

of

room

reflections

and

other

nearby

noise

sources.

The

declared

sound-power

levels

indicate

an

upper

limit,

below

which

a

large

number

of

computers

will

operate.

Chapter

1.

The

ThinkServer

TD100

and

TD100x

server

3