Lenovo ThinkServer TD100x User Manual

Page 78

Advertising
background image

Important:

The

server

might

malfunction

if

these

settings

are

incorrectly

configured.

Follow

the

instructions

on

the

screen

carefully.

This

choice

is

on

the

full

Configuration/Setup

Utility

menu

only.

–

CPU

Options

Select

this

choice

to

view

or

change

the

options

that

control

the

behavior

of

the

microprocessor.

–

PCI

Bus

Control

Select

this

choice

to

view

or

change

the

system

resources

that

are

used

by

the

installed

PCI

or

PCI-Express

devices.

–

RSA

II

Settings

This

choice

is

displayed

only

when

a

Remote

Supervisor

Adapter

II

SlimLine

is

installed

in

the

server.

Select

this

choice

to

view

the

DHCP

IP

address

and

settings

and

the

Remote

Supervisor

Adapter

II

SlimLine

MAC

address;

to

view

or

change

the

DHCP

control,

static

IP

address,

operating-system

USB

selections;

and

to

save

the

values

and

reboot

the

Remote

Supervisor

Adapter

II

SlimLine.

–

Baseboard

Management

Controller

(BMC)

Setting

Select

this

choice

to

change

the

Intelligent

Platform

Management

Interface

(IPMI)

settings

for

the

mini-BMC

controller.

-

IPMI

Specification

Version

This

nonselectable

item

displays

the

IPMI

specification

version.

-

BMC

Firmware

Version

This

nonselectable

item

displays

the

mini-BMC

firmware

version.

-

BMC

Build

Date

This

nonselectable

item

displays

the

date

that

the

mini-BMC

code

was

built.

-

BMC

Build

Level

This

nonselectable

item

displays

the

version

of

the

mini-BMC

code.

-

Existing

Event

Log

number

This

nonselectable

item

displays

the

number

of

entries

in

the

system-event

log.

-

BMC

POST

Watchdog

This

option

enables

or

disables

the

POST

watchdog.

Disabled

is

the

default

setting.

-

BMC

POST

Watchdog

Timeout

This

option

enables

or

disables

the

mini-BMC

POST

watchdog

timer.

-

System

-

BMC

Serial

Port

Sharing

Select

this

choice

to

specify

whether

the

serial

port

that

the

mini-BMC

uses

is

shared

with

the

other

system

components

or

is

dedicated

to

the

mini-BMC.

When

this

option

is

enabled,

the

mini-BMC

controls

the

serial

port

by

way

of

remote

commands.

If

this

option

is

disabled,

the

serial

port

is

assigned

to

the

mini-BMC,

unless

the

BMC

Serial

Port

Access

Mode

option

is

disabled.

-

BMC

Serial

Port

Access

Mode

Select

this

choice

to

set

the

mini-BMC

access

mode

for

the

system

serial

port.

Shared

is

the

default

setting.

You

can

choose

from

the

following

access

modes:

64

ThinkServer

TD100

and

TD100x

Types

4203,

4204,

4205,

4206,

6398,

6399,

6419,

and

6429:

User

Guide

Advertising
This manual is related to the following products: