3. The non-hot-swap hard disk drives are installed in the lower hard-disk-drive cage and are protected

by an EMI-protective panel. Press the small tab

1

on the EMI-protective panel from the bottom and

then pivot the EMI-protective panel upward to remove it from the chassis and gain access to the
non-hot-swap hard-disk-drive bays.

CPU

MEM

PSU

CPU

MEM

PSU

1

2

Figure 75. Removing the EMI-protective panel

4. Remove the server cover. See “Removing the server cover” on page 87.

5. Remove the front system fan 1. See “Replacing the front system fan” on page 157.

6. Locate the appropriate non-hot-swap hard-disk-drive bay. See “Server components” on page 25.

7. Touch the static-protective package that contains the new non-hot-swap hard disk drive to any

unpainted surface on the outside of the server. Then, take the new non-hot-swap hard disk drive and
the signal cable out of the package.

Note: Do not touch the circuit board on the hard disk drive.