Post error codes – Lenovo D400 Desktop IdeaCentre User Manual

Page 32

Advertising
background image

27

Hardware Maintenance Manual

POST error codes

Each time you power-on the home center, it performs a series of tests that
check the operation of the home center and some options. This series of tests is
called the Power-On Self-Test, or POST.
POST does the following operations.
• Checks some basic system board operations
• Checks the memory operation
• Verifies that the boot drive is working
If the POST detects a problem with a hardware component, the HDD status
LED indicators on the front panel will blink a series of codes.

The following table describes the POST error codes and suggested actions to
correct the detected problem.

Operating

condition

Error code

Description/Action

Bit 0

Bit 1

Bit 2

Bit 3

During system
boot

SATA controller failed
1. Reseat the following components:

- Hard disk drive
- Cable from the hard disk drive backplane

to the system board

2. Replace the following components one at a

time, in the order shown, restarting the
home center each time:

- Hard disk drive
- Cable from the hard disk drive backplane

to the system board

- Hard disk drive backplane
- System board