Error Messages

FORM CLAMP
CLOSED

The form clamp is in the
wrong position. Touch
START to reset the
position. Follow the
instructions on the screen.

FORM ROLLER ERROR The form roller is

jammed. Clear the jam
and continue.

(

see ‘Jam in the Trim

Area’ on page 74

)

FORM ROLLER NOT
PARKED

The form roller is in the
wrong position. Touch
START to reset the
position. Follow the
instructions on the screen.

GATHERING AREA
COVER OPEN

Close the gathering area
cover if you need to
operate the machine
online.

INVERTER ERROR

Check for a paper jam and
clear if necessary.
Touch STOP to clear the
message from the screen.
If the problem continues,
contact your service
engineer.

JAM AT BRIDGE
INFEED

There is a paper jam at the
infeed to the connecting
bridge. Clear the jam and
continue.

(

see ‘Clear Paper Jams

on page 68

)

JAM AT FORM
ROLLER

The form roller is
jammed. Open the folder
cover and remove the jam.

(

see ‘Jam in the Trim

Area’ on page 74

).

JAM BEFORE
TRIMMER

There is a book jammed
before the trimmer. Clear
the jam and continue.

(

see ‘’ on page 73

).

JAM IN CONNECTING
BRIDGE

There is a paper jam in the
connecting bridge. Clear
the jam and continue.

(

see ‘Jam in the

Connecting Bridge’ on
page 70

)

Problem

Cause

Solution