background image

Replacing Consumables

67

3

Support the bottom of the drum with your
hand, then carefully pull the cartridge
toward you and remove it.

"#

Dispose of the cartridge properly
according to your local
regulations.

Installing the New OPC Drum Cartridge

Attention

The OPC drum is extremely sensitive to bright light and direct sunlight.
Always leave it in its protective bag until you’re ready to install it. Any
exposure to light should be avoided, or permanent damage could
result.

Any damage resulting from mishandling of the OPC drum will void the
warranty of the OPC drum. Also, handle the cartridge carefully by its
sides so you don’t touch the surface (the green part) of the drum. The
drum is also extremely sensitive to hand oils and scratches, both of
which reduce print quality.

1

Remove the new OPC drum cartridge from its
carton.

Attention

Keep the protective sheet on the cartridge. Do not touch the
protective sheet on the photosensitive (green) surface or scratch the
surface. This could lower image quality.

Make sure the transfer belt release lever is still set to its top position
(11 o’clock).