Blodgett KLT-G Series User Manual

Page 11

Advertising
background image

11


3.0 OPERATION (Continued)


A. Lighting (Continued)

If after 36 seconds the burner fails to ignite or the “ignition light goes out, the system
goes into Safety Lockout. De-energize the system by setting the thermo

stat to “OFF”

for five minutes and try again.


1. Set the thermostat to desired temperature setting. When temperature setting has been

reached, the “IGNITION” pilot will go off, turning off the burner. The unit will then cycle on
and off to maintain set temperature.



DAILY SHUTDOWN

1.

Turn power switch “OFF.”


2.

Turn thermostat “OFF.”


COMPLETE SHUTDOWN


1. Turn pow

er switch “OFF.”


2.

Turn thermostat “OFF”.


3.

Turn power supply to unit “OFF”.


4.

Remove front access panel on left side and turn dial on combination valve to “OFF”.


5. Close manual gas shut off valve.


NOTE: When the kettle is tilted a safety switch will automatically turn off gas supply. The kettle
will not operate once it has been tilted.