0 service connections – Blodgett KLT-G Series User Manual

Page 4

Advertising
background image

4

1.0 SERVICE CONNECTIONS

29

[3

73

]

J

F

L

K

A

MINIMUM

4[102mm]

8.125 [206]

27.75 [705]

10.5[267]

B

35

[889]

26

[660]

G

C

(GLT-20) 6.25[159]

(GLT-30...60) 7[178]

N

5.875[149]

3[76]

2[51]

H

36

[914]

E

M

D

6[152]

FLANGED FOOT DETAIL

2

7/16" [11mm] HOLES

ON 2.5 [63] B.C.

EQUALLY SPACED

Ø

DIMENSIONS ARE IN INCHES [MM]

Supply gas through 3/4" pipe . A gas shut-off valve must be installed in supply piping convenient and adjacent to appliance.

Unless other wise specified, Field Wire Electrical Connection to be 120 Volts, 60 Hertz single phase with grounding wire.

COLD WATER: 3/8"(10mm) tubing to faucet (OPTIONAL)

HOT WATER: 3/8"(10mm) tubing to faucet (OPTIONAL)

DIMENSIONS

394

15.5

419

495

19.5

16.5

152 litres

CAPACITY

227 litres

KLT-60G

KLT-40G

60 gallons

40 gallons

KLT-20G

MODEL

76 litres

20 gallons

1108

43.63

1159

45.63

660

762

mm

inches

inches

mm

30

26

1499

59

1099

43.25

1115

43.88

454

419

16.5

17.88

2083

1930

76

82

1032

C

40.63

508

inches

mm

20

A

48.13

1222

B

1019

E

40.13

483

D

19

1943

F

76.5

565

565

22.25

22.25

140

584

191

5.5

7.5

584

23

23

1156

1080

45.5

42.5

G

24

610

H

11

279

J

22

559

K

40.5

1029

L

M

18.38

467

629

24.75

30.5

775

N

648

25.5

562

22.13

724

28.5

UNITS

55.25

1403

KLT-20G

MODEL

6"-14" (152-356mm)

SUPPLY PIPE PRESSURE (W.C.)

11"-14" (279-356mm)

Propane

Natural

GAS SUPPLY

KLT-40G

KLT-60G

kW/HR.

23.4

80,000

120,000

100,000

35.2

29.3

BTU/HR.

Advertising