6.0 SERVICE (Continued)



TO ADJUST PRESSURE SWITCH:

1. To obtain access to the pressure switch, the front panel must be removed. Remove the

screws on bottom of the panel. Be sure to support the panel to avoid excessive strain on
the wiring.


2. To increase the pressure switch setting, turn the white ribbed knob clockwise; to decrease,

turn it counterclockwise. Use the centre of the black ring as an indicator.


3. With the kettle empty and completely cold, turn kettle on and set thermostat to maximum

setting (275

F).


4. The pressure in kettle (read pressure gauge on front panel) should reach a maximum of 30

psi and pressure relief valve should not open. Kettle pressure may rise 3 or 4 psi even after
burners shut down.


5. Relief valve should not open when kettle pressure is 45 psi; pressure switch setting is

satisfactory.


6. If the safety relief valve opens, reduce setting on pressure switch, cool kettle completely by

running cold water through it and repeat steps 3 - 6.


7. If pressure in kettle is below 30 psi increase setting of pressure switch, cool kettle

completely by running cold water through it and repeat steps 3 - 7.


8. Allow the kettle to cycle several times to verify the correct pressure setting.

9. Replace the front panel when adjustment is complete.