Blodgett KLT-G Series User Manual

Page 21

Advertising
background image

21


6.0 SERVICE

GENERAL

When any difficulty arises always check that the unit has been connected to the gas supply type
and voltage for which it was supplied. This can be done by examining the serial plate on the
lower right side of the unit. It will list the gas type and voltage for which the unit was
manufactured.

Wiring diagrams for the unit are located in a small envelope affixed to the side panel of left hand
console.

Orifice Size

Unit

Total Input

Natural

Propane

KLT-20G

80,000 BTU/Hour

DMS # 19 (.166")

DMS # 30 (.125")

KLT-40G

100,000 BTU/Hour

DMS # 13 (.185")

DMS # 27 (.144")

KLT-60G

120,000 BTU/Hour

DMS # 7 (.201")

DMS # 23 (.154")


MANIFOLD PRESSURE

Natural Gas - 3.5 inches W.C.

LP Gas - 4 inches W.C.


ADJUSTMENTS

WARNING: Adjustments and service work may be performed only by a qualified
technician who is experienced in, and knowledgeable with, the operation of
commercial gas cooking equipment. To assure your confidence, contact your
authorized service agency for reliable service, dependable advice or other
assistance, and for genuine factory parts.