Blodgett KLT-G Series User Manual

Page 26

Advertising
background image

26

7.0 TROUBLESHOOTING

PROBLEM

LOOK FOR

Motor will not run.

S No current. Check that power is being

supplied to the unit.

S Defective thermostat or pressure switch.
S Defective motor.
S Motor overload out.
S Blown fuse.

Motor runs, no spark.

S Defective transformer.
S Defective ignition module.
S Blown fuse on ignition module.
S Defective spark electrode (cracked

insulator).

S Defective ignition cable.
S Defective centrifugal switch on motor.

Motor runs, spark present, no gas ignition.

S Manual main valve off.
S Mislocated spark or ground rods. See

Figure 2 for correct position

S Defective valve.
S Defective ignition module.
S Burner rate set too high. Ensure that

manifold pressure is set per rating plate
and that correct orifice size installed (See
table page 21.

S Burner getting too much air. Reduce air

shutter opening (not below 1.0).

Low water light comes on.

S Add water - See previous section

ADJUSTMENTS.

Relief valve opens.

S Pressure switch set too high.
S Pressure gauge is not accurate.
S Relief valve is faulty