7 remote control functions, 2microwave field tilt angle – BEA IS40P User Manual

Page 3

Advertising
background image

75.5371.01 EN 20080505 (75.5370)

Page 3 of 6

2

Microwave Field Tilt Angle

-

3.25

6.50

9.75

13.0

19.7

23.0

26.3

16.3

3.25

0

3.25

6.50

6.50

ft

ft

Mounting height: 16 ft.

Sensitivity: 9

Sensor angle: 20°

-

+

MIN

MAX

By turning the tilt

angle adjustment

screw clockwise,

the radar field

angle is reduced.

By turning the tilt

angle adjustment

screw counter

clockwise, the

radar field angle

is increased.

7 Remote Control Functions

Every programming session begins by unlocking the sensor. Thereafter a program setting may be altered by pressing the desired function key

followed by the desired value for that function. When all programming is complete press the lock key twice to retain settings. Use the following

as a guide:

Unlock

the sensor to enter into adjustment

session (if no access code has been entered)

To change the value of a parameter

(ex. Automatic Learn Time)

… to change any other parameters

(ex. Relay Configuration)

To check the value of a parameter (ex.

Automatic Learn Time)

Lock

the adjustment session and go back to

normal function

Press Unlock Key

RED LED

Flashes Slowly

Select Parameter

to Change

RED LED

Flashes Quickly

Enter New Value

RED LED

Flashes Slowly

Select Parameter

to Change

RED LED

Flashes Quickly

Enter New Value

RED LED

Flashes Slowly

Select Parameter

to Check

RED LED

Flashes Quickly

Press Question

Mark

The Number of Green Flashes Indicate

the Value of This Parameter

RED LED

Flashes Slowly

Press Lock Key Twice

OR

+ Lock Code

0-9

0-9

?