Remote Control Parameters (Continued)

FUNCTION

AFFECTS

INFRARED OR

MICROWAVE

REMOTE

CONTROL

BUTTON

FUNCTION DESCRIPTION

SENSITIVITY

MICROWAVE

0 - 9: (7 - Default)

DETECTION
MODE

MICROWAVE

1: Bidirectional (Towards or Away from Sensors)

2: Unidirectional Approach (Towards Sensor)

3: Unidirectional Depart (Away from Sensor)

REJECTION
MODE

MICROWAVE

1: Detection of all kind of Targets

in Motion

2: Detection of all kind of Targets in Motion

+ Interference Immunity

3: Low ‘Pedestrian/Parallel traffic’ Rejection

+ Interference Immunity

4: Medium ‘Pedestrian/Parallel traffic’

Rejection + Interference Immunity

5: High ‘Pedestrian/Parallel traffic’ Rejection

+ Interference Immunity

ACTIVATION
RELAY
HOLD TIME

MICROWAVE

0: 0.5 second

1: 1.0 second

2: 2.0 seconds

3: 3.0 seconds

4: 4.0 seconds

5: 5.0 seconds

6: 6.0 seconds

7: 7.0 seconds

8: 8.0 seconds

9: 9.0 seconds

RELAY
CONFIGURATION

INFRARED

MICROWAVE

Description

Active

Passive

Detection

COM

COM

No Detection

COM

COM

NO

NC

NO

NC

NO

NC

NO

NC

Activation

Relay

Presence

Relay

1

Active

Passive

2

Passive

Active

3

Passive

Passive

4

Active

Active

OUTPUT
CONFIGURATION

INFRARED

MICROWAVE

PRESENCE RELAY

IS40

IS40P

0 - 4: ALL MODES

Activates when object is in

presence zone.

Activates when object is

in presence zone.

ACTIVATION RELAY

IS40

IS40P

0: STANDARD MODE

Activates when motion

detected.

Activates when object is

in presence zone.

1: PULSE ON ENTRY

Activates if object motion is

detected and then object enters

presence zone.

Activates when object

enters presence zone.

2: PULSE ON EXIT

Activates if object motion is

detected and then object exits

presence zone.

Activaties when object exits

presence zone.

3: PULSE ON ENTRY

FIRST / LAST LINE

(See Example to the Left)

Activates if object motion is

detected and then object enters

presence zone (first or last line).

Activates when object

enters presence zone (first

or last line).

4: PULSE ON EXIT

FIRST / LAST LINE

(See Example to the Left)

Activates if object motion is

detected and then object exits

presence zone (first or last line).

Activates when object exits

presence zone (first or last

line).

SETUP

INFRARED

MICROWAVE

Initiate Setup, press

DEFAULT
VALUES

INFRARED

MICROWAVE

To set Factory Defaults, press

DOOR EXAMPLE

LAST LINE

FIRST LINE

F1

75.5371.01 EN 20080505 (75.5370)

Page 5 of 6

6 3 0 3 6

3

6
9
12
15
18

Height = 16 ft.

S = 3

S = 9

S = 6

FT.

Sensitivity 9, 6, 3

9

0