8 setup & startup, 2remote control parameters, F2 1 setup sequence – BEA IS40P User Manual

Page 4

Advertising
background image

Page 4 of 6

75.5371.01 EN 20080505 (75.5370)

2

Remote Control Parameters

FUNCTION

AFFECTS

INFRARED OR

MICROWAVE

REMOTE

CONTROL

BUTTON

FUNCTION DESCRIPTION

AUTOMATIC
LEARN TIME

INFRARED

0: 30 seconds

1: 1 minute

2: 2 minutes

3: 5 minutes

4: 10 minutes

5: 20 minutes

6: 60 minutes

9:

(Infi nity)

IMMUNITY

INFRARED

1: Low (Normal)

2: Medium (Rain)

3: High (Snow)

PATTERN

INFRARED

FREQUENCY

INFRARED

1: L - L’ Pulse Frequency

2: H - H’ Pulse Frequency

TARGET SIZE

INFRARED

Defi ne the Minimum Target Size

8 Setup & Startup

6

7

8

9

DOOR

DOOR

DOOR

DOOR

DOOR

DOOR

DOOR

DOOR

DOOR

F2

1

Setup Sequence

1. Power on the sensor. Sensor automatically performs a Setup on power up and Setup is complete when Red/Green fl ashing stops.

2. If the Detection Zone (Background) permanently changes and a new Setup is required, perform a new Setup by pressing

. Red & Green LEDs will blink rapidly until setup is complete.

NOTE

: Avoid movement in the IR zone during setup.

0

0

1 x 1

1:

2 x 2

2:

3 x 3

3:

4 x 4

4:

1 x 2

5:

2 x 3

6:

3 x 2

7:

1

2

3

4

5

6

7

8

9

Advertising