Uninterruptible power supply unit (ups), 1 activate the server and press the <delete> key, 3 set “ac back function” to “full-on – Toshiba Magnia 550d User Manual

Page 118: 4 press the <esc> key, 6 press the <y> key and then <enter> key

Advertising
background image

Connecting Hardware Devices

Uninterruptible power supply unit (UPS)

101

Uninterruptible power supply unit (UPS)

When connecting the server to an uninterruptible power supply
unit (UPS), use the UPS recommended by Toshiba.

When restarting a server connected using a UPS after power
failure, use the BIOS Setup Utility as follows.

1 Activate the server and press the <Delete> key.

The BIOS screen is displayed

2 Select “POWER MANAGEMENT SETUP” and press the

<Enter> key.

3 Set “AC Back Function” to “Full-On.”

4 Press the <Esc> key.

5 Select “SAVE & EXIT SETUP” and press the <Enter> key.

6 Press the <Y> key and then <Enter> key.

The data on the revised setting is saved and the server restarts.

Advertising