Installing the heat sink, 10 replace the side panel and front door panel – Toshiba Magnia 550d User Manual

Page 75

Advertising
background image

Connecting Hardware Devices
CPU module

58

Installing the heat sink

NOTE: Do not push the fin section of CPU heat sink module.
This may cause the deformation of the heat sink.

Do not detach the heat sink once attached. The cooling
efficiency of a heat sink decreases if detached and
reattached. Therefore, if the heat sink is detached for some
reason, do not reattach it but attach a new one.

9 Connect the fan cable to the J15 connector of the motherboard.

The fan cable for the standard CPU (CPU1) is connected to the
J13 connector.

10 Replace the side panel and front door panel.

11 Plug in the power cable and switch on the server.

12 Check that the newly installed additional CPU module is

correctly recognized on the monitor screen.

When the additional CPU module is correctly recognized, its
information is displayed on the screen as shown below.

(In this case one 1 GHz CPU is installed)

Pentium III - 1GHz

guideline
(for 1 GHz CPU
module)

gap

Advertising