X-Ring

X-Ring provides network redundancy similar to the Spanning Tree and

Rapid Spanning Tree Protocols. However, recovery time is greatly reduced

when the X-Ring protocol is used. The protocol identifies one switch as the

Ring Master. Packets are blocked from the redundant path unless a ring

member becomes disconnected from the rest of the network. When this

happens, the protocol automatically restores connectivity using the

redundant path.

In the X-Ring topology, every switch should enable X-Ring function and

assign two member ports to the ring. Only one switch in the X-Ring group

would be set as the backup switch. Other switches are called working

switches and their two member ports are called working ports. If a network

connection failure occurs, the backup port will automatically become a

working port to recover.

The switch can be set in the ring master or slave mode. The ring master

negotiates and places commands to the other switches in the X-Ring group.

If there are two or more switches in the master mode, the software will

select the switch with lowest MAC address number as the ring master. The

X-Ring master mode is enabled using the X-Ring configuration interface.

The Ring Master can also be identified using the R.M. LED on the front of

the switch.

The switch also supports coupling ring to connect two or more X-Ring

groups for redundant backup. The dual homing function is used to prevent a

connection lose between the X-Ring group and the upper level/core switch.

„

Enable X-Ring: Mark the check box to enable the X-Ring function.

„

Enable Ring Master: Mark the check box to set the switch as the Ring

Master.

„

1

st

& 2

nd

Ring Ports:

Assign two ports as the member ports. 1

st

Ring

Port

is the working port and 2

nd

Ring Port

is the backup port. When 1

st

Ring Port

fails, the system will automatically upgrade the 2

nd

Ring

Port

to be the working port.