Misc Configuration

„

Quiet Period: Sets the period during which the port does not try to

acquire a supplicant.

„

TX Period: Sets the period that the port waits before retransmitting the

next EAPOL PDU during an authentication session.

„

Supplicant Timeout: Sets the period the switch waits for a supplicant

response to an EAP request.

„

Server Timeout: Set the period the switch waits for a server response

to an authentication request.

„

Max Requests: Sets the number of authentications that time-out

before authentication fails and the authentication session ends.

„

Reauth period: Set the period of time after which connected clients

must be re-authenticated.

„