Serial Card Setup

Manual Documentation Number 3PCIoUx-1008

Chapter 2

11

Setting the DIP Switches on RS-232/422/485 Ports

Set the DIP switches to configure the desired operating mode as follows:

422/485

TX On

RX On

232

TX SD

RX SD

Switch 1

Switch 2

Switch 3

RS-232 Mode

422/485

TX On

RX On

232

TX SD

RX SD

RS-422 Mode

422/485

TX On

RX On

232

TX SD

RX SD

4-wire RS-485 Mode

422/485

TX On

RX On

232

TX SD

RX SD

2-wire RS-485 Mode

Figure 5. RS-232/422/485 DIP Switch Settings.

DIP Switch 1 (RS-232/422/485 ports)

The top DIP switch (1) configures the port for RS-232 or RS-422/485
operation. This switch is the only one that is required to be set for RS-232
operation. The positions of switches 2 and 3 do not matter when switch 1 is
set for RS-232 operation.

DIP Switch 2 (RS-232/422/485 ports)

The middle DIP switch (2) configures the port for RS-485 or RS-422
operation. For RS-422 operation (which uses two wire pairs and sends point-
to-point or point-to-multipoints) the transmitter can be enabled all the time.
Placing the middle DIP switch in the TX ON position accomplishes this.

For RS-485 operation the middle DIP switch is placed in the TX SD position.
In this position the transmitter is only enabled when data is being sent. The
transmitter is tri-stated when not sending data, allowing other transmitters on
the communications line to transmit without interference.

Advertising