Manual Documentation Number 3PCIoUx-1008

UART will request that the computer transfer the contents of the buffer to
program memory. This is intended to optimize the throughput of the data.
The default value is 14. Usually this parameter does not have to be changed.

Setting the RTS Control Parameter

1. Set

RTS Control

to Normal for RS-232; set

RTS Control

to RS-

485 Mode for 2-wire or 4-wire RS-485 operation. Either setting can
be used for RS-422.

Typically the COM parameters set in this dialog box are overridden
by the software application.

Note: For proper operation the DIP switches on the PCI card must be

set for the same mode. Refer to Chapter 2 for more information on
configuring the DIP switches.

2. The

Direction control delay (bit times)

box allows you to set the

length of time the Transmit driver continues to be enabled after the
last bit of data in the transmit register has been sent. The purpose of
this setting is to maintain the transmission line in a know (idle) state
until the data has reached its destination. If the line is released too
soon it can pick up noise that could cause problems on the
communications system. This parameter is preset to a value of 10
bit times and typically will not have to be changed. For longer
transmission lines this value may have to be increased.

Setting the Hardware Handshaking Level

The

Hardware handshaking Hysteresis level (characters)

parameter

allows you to set how long the local UART will continue to accept data after
its receive buffer has reached the point at which it asks the computer to
transfer the data to program memory. When this point is reached the UART
de-asserts the RTS hardware handshake line (which is connected to the
remote UART’s CTS line), stopping the remote device from sending data
until its CTS line is re-asserted. This will occur when the local receive FIFO
buffer has been cleared. The default value for this parameter is 0. Typically
this value will not need to be changed.

Changing the COM Port Name/Number

1. To change the COM port number assigned to the port, click the

COM Port Name

arrow and select the new

COM Port Name

from

the list.