Baumfolder Baumcut Programmable 26.4 User Manual

Page 43

Advertising
background image

K5A - 9

Program data display:

5.0 Automatic Operation

after 1. input:

input section shows 30.735

after 2. input:

backgauge moves

after backgauge stops:

measurement display shows 30.735

Conditions: Automatic OFF

A Measurement input with metric system (cm)

Example:

Size

Key input

1.

30,735

2.

Positioning, press

2 x shortly

________________________________________________________________

B Measurement input in inches

Same way of input as for metric system
however
value in inches entered as a fraction:

Example:

Size

Key input

1.

12

1/2

"

2.

Positioning, press

2 x shortly

Note:
For whole sizes (no digits behind decimal point) zeroes do not have to be
keyed in. This is done automatically.

Automatic Backgauge Adjustment through Numerical Keyboard