Programming

Mic Set Up

This function lets you set the Microphone features:

• Precedence Activation:

N.O. = Normally Open - requires short between precedence terminals
to activate mic
N.C. = Normally Closed - requires short between precedence terminals
to deactivate mic
VOX = Voice Activated switch activation)

• Automatic Level Control (ALC)
• Phantom Power (PPS)
• For MIC B, it also permits setting the input as a transformer-balanced

600-Ohm input for telephone paging applications.

Note: Changes made during MIC Setup will not be activated
until you exit the programming mode.

The factory defaults are listed below:
Feature

MIC A

MIC B

Precedence Activation

VOX

VOX

Automatic Level Control

On

On

Phantom Power

On

On

1.

Enter the programming mode and press the NEXT or BACK buttons

until MICROPHONE appears on the display.

2.

Press ENT to enter the function.

To Set MIC Parameters

1.

Select the Mic to be configured
by pressing either the MIC A or
MIC B buttons. If, for example,
you press MIC A, the display
shows the precedence setting for
MIC A:

A PREC VOX

, which indicates

that the MIC A-precedence acti-
vation is set to VOX.

2.

Press the NEXT or BACK buttons to scroll available options:

VOX, N.O.

and

N.C

.

3.

Press ENT to store the selection and proceed to the next feature. The
PROG LED will blink to indicate that data was stored.

A PREC VOX

26